Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Colorimetric assay of matrix metalloproteinase activity based on metal-induced self-assembly of carboxy gold nanoparticles

Authors
Kim, Gae BaikKim, Kun HeePark, Yeon HeeKo, SunghoKim, Young-Pil
Issue Date
Mar-2013
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Gold nanoparticle; Colorimetric assay; Self-assembly; Matrix metalloproteinase; Metal affinity
Citation
BIOSENSORS & BIOELECTRONICS, v.41, pp.833 - 839
Indexed
SCIE
SCOPUS
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
41
Start Page
833
End Page
839
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163320
DOI
10.1016/j.bios.2012.10.025
ISSN
0956-5663
Abstract
Among proteases, matrix metalloproteinases (MMPs) have been of significant interest because they are considered as one of the promising biomarkers in association with cancer metastasis, inflammation and other degenerative diseases. Many attempts based on the optical sensing have been made to analyze the activity of MMPs, but most of them require an expensive fluorescence readout and a labor-intensive process. To circumvent this issue, we demonstrated a simple calorimetric detection of protease activity by using carboxy gold nanoparticles (AuNPs) and histidine-containing peptides via metal-affinity coordination. Due to their higher surface-to-volume ratio, the nanometer size of AuNPs enables the surface ligands to function like a chelator, providing greater affinity with metal ions, even in the absence of chelators. With no additional modification by multidentate ligands, the carboxy AuNPs were easily aggregated and changed in color (from reddish-brown to violet) after adding peptide substrates with hexahistidine at both ends and metal ions, whereas the presence of proteases in solution prevented NP aggregation by cleaving the peptides, thereby retaining the original color of the AuNPs. When the extinction ratio (E-520/E-700) of the AuNP solution was measured as a function of matrix metalloproteinase concentration in a single reaction, there was good linearity from as low as 3 nM to 52 nM. This approach is anticipated to be useful in designing other diagnostic nanosensors.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 생명과학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.