Abstract
The central purpose of this research was to propose spray tower dehumidification effectiveness correlations useful for liquiddesiccant integrated system design and analysis. In this research, Liquid desiccant air conditioning system performance datagenerated using established literature reviews were statistically analyzed by design expert. The normal common desiccantsolutions; TEG and common types of tower; spray tower, were analyzed. Proposed correlations relates the spray towerdehumidification effectiveness as a function of five parameters; L/G(Liquid to gas ratio), inlet air and solution temperature, inletair relative humidity, solution concentration.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE