실험계획법을 이용한 Spray Tower 제습효율 예측모델에 관한 연구A study on the propose of Spray tower dehumidification prediction model by using Design of Experiments
- Other Titles
- A study on the propose of Spray tower dehumidification prediction model by using Design of Experiments
- Authors
- 박준영; 김민휘; 정재원
- Issue Date
- Oct-2012
- Publisher
- 대한건축학회
- Keywords
- 액체 제습기; 분무탑식 제습기; 모델링; 제습 공조; Liquid desiccant; Spray Tower; Modelling; Desiccant air conditioning
- Citation
- 대한건축학회 추계학술발표대회논문집, v.32, no.2, pp.331 - 332
- Indexed
- OTHER
- Journal Title
- 대한건축학회 추계학술발표대회논문집
- Volume
- 32
- Number
- 2
- Start Page
- 331
- End Page
- 332
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164437
- ISSN
- 2287-5786
- Abstract
- The central purpose of this research was to propose spray tower dehumidification effectiveness correlations useful for liquiddesiccant integrated system design and analysis. In this research, Liquid desiccant air conditioning system performance datagenerated using established literature reviews were statistically analyzed by design expert. The normal common desiccantsolutions; TEG and common types of tower; spray tower, were analyzed. Proposed correlations relates the spray towerdehumidification effectiveness as a function of five parameters; L/G(Liquid to gas ratio), inlet air and solution temperature, inletair relative humidity, solution concentration.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > 서울 건축공학부 > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164437)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.