Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Comparison of Cornell and Sokolow-Lyon Electrocardiographic Criteria for Left Ventricular Hypertrophy in Korean Patientsopen access

Authors
Park, Jin KyuShin, Jeong HunKim, Seok HwanLim, Young-HyoKim, Kyung-SooKim, Soon GilKim, Jeong HyunLim, Heon GilShin, Jinho
Issue Date
Sep-2012
Publisher
KOREAN SOC CARDIOLOGY
Keywords
Electrocardiography; Echocardiography; Hypertrophy, left ventricular; Sensitivity and specificity
Citation
KOREAN CIRCULATION JOURNAL, v.42, no.9, pp.606 - 613
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN CIRCULATION JOURNAL
Volume
42
Number
9
Start Page
606
End Page
613
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164835
DOI
10.4070/kcj.2012.42.9.606
ISSN
1738-5520
Abstract
Background and Objectives: Electrocardiography (ECG) is a cost-effective and useful method for diagnosing left ventricular hypertrophy (LVH) in a large-scale study or in clinical practice. Among ECG criteria, the Cornell product (Cor P) and Sokolow-Lyon criteria were adopted by the European Society of Hypertension-European Society of Cardiology Guidelines but have different performances among races. The aim of this study was to compare the diagnostic performance of two voltage criteria in Korean patients. Subjects and Methods: Electrocardiography and echocardiographic LV mass of 332 (159 male, 173 female) consecutive patients were analyzed. Cornell voltage criteria and the Cor P were compared with Sokolow-Lyon voltage (Sok V) and the Sokolow-Lyon product (Sok P). The sensitivities and specificities were estimated using a receiver-operating characteristics (ROC) curve in relation to the LVH diagnosis. The sensitivities and revised cut-off values were derived at specificity levels of 90, 95, and 100%. Results: The Cornell-based criteria generally showed better performance than that of the Sok V criteria and Sok P in the area under the ROC curve analysis. The revised cut-off values for the Cornell voltage criteria (20 and 16 mm for males and females, respectively) showed an improved sensitivity (19.7 and 30.3% for males and females, respectively), with a high specificity of 95%. Conclusion: The Cornell-based criteria had better performance than that of the Sokolow-Lyon criteria in both Korean men and women. However, revised cut-off values are needed to improve accuracy.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jin Kyu photo

Park, Jin Kyu
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE