Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Transmission Raman measurement directly through packed corn kernels to improve sample representation and accuracy of compositional analysis

Authors
Shin, KayeongChung, HoeilKwak, Chul-won
Issue Date
Aug-2012
Publisher
Royal Society of Chemistry
Citation
Analyst, v.137, no.16, pp 3690 - 3696
Pages
7
Indexed
SCI
SCIE
SCOPUS
Journal Title
Analyst
Volume
137
Number
16
Start Page
3690
End Page
3696
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164961
DOI
10.1039/c2an35443h
ISSN
0003-2654
1364-5528
Abstract
The potential of transmission Raman spectroscopy for direct analysis of packed granular samples, one of the most frequently encountered sample types in the field of non-destructive spectroscopic analysis, has been evaluated. For this purpose, transmission Raman spectra were collected by laser illumination through packed corn kernels to determine their protein concentration. Back-scattering Raman spectra of the same samples were also collected for comparison. Raman spectral features of the major kernel constituents were initially characterized, and Raman mapping over the whole kernel face was performed to investigate the inhomogeneous distribution of constituents in a kernel. Possible variations of transmission spectral features depending on the laser illumination on different locations of a kernel were investigated, since the orientation of kernels in the packing was essentially random. Rotation of kernel packing during spectral collection was helpful in improving the compositional representation of packed kernels. With partial least squares (PLS) regression, the protein concentrations were determined using both spectral collection methods and the resulting accuracies were compared. As a result, the transmission measurement provided a more accurate determination of protein concentration since it enabled deeper sampling across the packed kernels, leading to a better compositional representation of them. By contrast, in the back-scattering measurement, kernels on the top of the packing were mainly sampled for the spectral acquisition. Moreover, the back-scattering spectral feature, more weighted to constituents localized at the outer portion of a kernel, was short of representing the overall composition of a kernel.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE