Effect of a metal electrode on the radiation tolerance of a SiC neutron detector
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Junesic | - |
| dc.contributor.author | Shin, Hee-Sung | - |
| dc.contributor.author | Kim, Ho-Dong | - |
| dc.contributor.author | Kim, Han Soo | - |
| dc.contributor.author | Park, Se Hwan | - |
| dc.contributor.author | Lee, Cheol Ho | - |
| dc.contributor.author | Kim, Yong Kyun | - |
| dc.date.accessioned | 2022-07-16T14:24:15Z | - |
| dc.date.available | 2022-07-16T14:24:15Z | - |
| dc.date.issued | 2012-08 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164992 | - |
| dc.description.abstract | The Korea Atomic Energy Research Institute (KAERI) has developed a silicon carbide (SiC) diode as a neutron detector that can be used in harsh environments such as nuclear reactor cores and spent fuel. The radiation tolerance of the SiC detector was studied in the present work. Especially, the effect of a metal electrode on the radiation tolerance of the SiC detector was studied. Four different types of SiC detectors were fabricated, and the operation properties of the detectors were measured and compared before and after neutron irradiations of 2.16 x 10(15) n/cm(2) and 5.40 x 10(17) n/cm(2). From the comparison, the detector with a Ti/Au electrode structure showed the highest radiation tolerance among detectors. A detector assembly was fabricated using two types of SiC p-i-n diode detectors: one containing (LiF)-Li-6 and the other without it. Signals from the detectors were measured in the current mode to minimize the noise of the detector. Signal currents from detectors were measured for neutron fluxes ranging from 5.54 x 10(6) n/cm(2) s to 2.86 x 10(8) n/cm(2) s and gamma doses up to 100 Gy/h. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Effect of a metal electrode on the radiation tolerance of a SiC neutron detector | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.61.330 | - |
| dc.identifier.scopusid | 2-s2.0-84866402382 | - |
| dc.identifier.wosid | 000307441500005 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.61, no.3, pp 330 - 335 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 61 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 330 | - |
| dc.citation.endPage | 335 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001687036 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordPlus | CARBIDE SEMICONDUCTOR-DETECTORS | - |
| dc.subject.keywordAuthor | Silicon carbide | - |
| dc.subject.keywordAuthor | Neutron detector | - |
| dc.subject.keywordAuthor | Thermal neutron flux monitor | - |
| dc.identifier.url | https://link.springer.com/article/10.3938%2Fjkps.61.330 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.