Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effect of a metal electrode on the radiation tolerance of a SiC neutron detector

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Junesic-
dc.contributor.authorShin, Hee-Sung-
dc.contributor.authorKim, Ho-Dong-
dc.contributor.authorKim, Han Soo-
dc.contributor.authorPark, Se Hwan-
dc.contributor.authorLee, Cheol Ho-
dc.contributor.authorKim, Yong Kyun-
dc.date.accessioned2022-07-16T14:24:15Z-
dc.date.available2022-07-16T14:24:15Z-
dc.date.created2021-05-12-
dc.date.issued2012-08-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164992-
dc.description.abstractThe Korea Atomic Energy Research Institute (KAERI) has developed a silicon carbide (SiC) diode as a neutron detector that can be used in harsh environments such as nuclear reactor cores and spent fuel. The radiation tolerance of the SiC detector was studied in the present work. Especially, the effect of a metal electrode on the radiation tolerance of the SiC detector was studied. Four different types of SiC detectors were fabricated, and the operation properties of the detectors were measured and compared before and after neutron irradiations of 2.16 x 10(15) n/cm(2) and 5.40 x 10(17) n/cm(2). From the comparison, the detector with a Ti/Au electrode structure showed the highest radiation tolerance among detectors. A detector assembly was fabricated using two types of SiC p-i-n diode detectors: one containing (LiF)-Li-6 and the other without it. Signals from the detectors were measured in the current mode to minimize the noise of the detector. Signal currents from detectors were measured for neutron fluxes ranging from 5.54 x 10(6) n/cm(2) s to 2.86 x 10(8) n/cm(2) s and gamma doses up to 100 Gy/h.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleEffect of a metal electrode on the radiation tolerance of a SiC neutron detector-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yong Kyun-
dc.identifier.doi10.3938/jkps.61.330-
dc.identifier.scopusid2-s2.0-84866402382-
dc.identifier.wosid000307441500005-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.61, no.3, pp.330 - 335-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume61-
dc.citation.number3-
dc.citation.startPage330-
dc.citation.endPage335-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001687036-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusCARBIDE SEMICONDUCTOR-DETECTORS-
dc.subject.keywordAuthorSilicon carbide-
dc.subject.keywordAuthorNeutron detector-
dc.subject.keywordAuthorThermal neutron flux monitor-
dc.identifier.urlhttps://link.springer.com/article/10.3938%2Fjkps.61.330-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE