Cited 0 time in
Cosmic ray measurement and experimental temperature analysis with a muon detector
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Yun Ho | - |
| dc.contributor.author | Kang, Jeongsoo | - |
| dc.contributor.author | Jang, Doh-Yun | - |
| dc.contributor.author | Son, Jae Bum | - |
| dc.contributor.author | Kim, Yong-Kyun | - |
| dc.date.accessioned | 2022-07-16T14:25:17Z | - |
| dc.date.available | 2022-07-16T14:25:17Z | - |
| dc.date.issued | 2012-08 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/165002 | - |
| dc.description.abstract | The Basic Atomic Energy Research Institute (BAERI) of Hanyang University in Korea constructed and operates a cosmic ray detection system. In this study, a muon detector composed of a plastic scintillator and a wavelength shifter was used to obtain data over a total of six experimental periods. Using the collected data, we analyzed the response dependence of the developed muon detector on the laboratory's environmental temperature. The detection results showed a correlation coefficient of over 0.7, as well as a negative proportional correlation in the experiments in which the thermostat did not operate. We performed a correction for the laboratory's environmental temperature and analyzed the correlation between the muon count rate and the atmospheric pressure. As a result, we obtained a barometric coefficient of -0.1191 +/- 0.0054%/hPa. The analyzed data were compared with data from the eighteen NM64 type neutron monitors at our station. The correlation coefficient between the two detection systems was approximately 0.8046, confirming that the response changes were roughly identical to response of neutron monitors. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Cosmic ray measurement and experimental temperature analysis with a muon detector | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.61.647 | - |
| dc.identifier.scopusid | 2-s2.0-84866100292 | - |
| dc.identifier.wosid | 000308328900026 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.61, no.4, pp 647 - 652 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 61 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 647 | - |
| dc.citation.endPage | 652 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001693542 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordAuthor | Cosmic ray | - |
| dc.subject.keywordAuthor | Muon detector | - |
| dc.subject.keywordAuthor | Plastic scintillator | - |
| dc.subject.keywordAuthor | Wavelength shifter | - |
| dc.subject.keywordAuthor | Barometric coefficient | - |
| dc.identifier.url | https://link.springer.com/article/10.3938%2Fjkps.61.647 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.