Cited 0 time in
Effect on Critical Dimension Performance for Carbon Contamination of Extreme Ultraviolet Mask Using Coherent Scattering Microscopy and In-situ Contamination System
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Doh, Jonggul | - |
| dc.contributor.author | Lee, Sangsul | - |
| dc.contributor.author | Lee, Jaewook | - |
| dc.contributor.author | Hong, Seongchul | - |
| dc.contributor.author | Jeong, Chang Young | - |
| dc.contributor.author | Lee, Dong Gun | - |
| dc.contributor.author | Kim, Seong-Sue | - |
| dc.contributor.author | Ahn, Jinho | - |
| dc.date.accessioned | 2022-07-16T15:08:09Z | - |
| dc.date.available | 2022-07-16T15:08:09Z | - |
| dc.date.issued | 2012-06 | - |
| dc.identifier.issn | 0021-4922 | - |
| dc.identifier.issn | 1347-4065 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/165409 | - |
| dc.description.abstract | The impact of carbon contamination on imaging performance was analyzed using an in-situ accelerated contamination system (ICS) combined with coherent scattering microscopy (CSM) which was installed at 11B extreme ultraviolet lithography (EUVL) beamline of the Pohang Accelerator Laboratory (PAL). The CSM/ICS is composed of CSM for measuring imaging properties and ICS for implementing acceleration of carbon contamination. The mask critical dimension (CD) and reflectivity were compared before and after carbon contamination through accelerated exposure. The reflectivity degradation was measured as 1.3, 2.0, and 2.8% after 1, 2, and 3 h exposure, respectively, due to carbon contamination of 5, 10, and 20 nm as measured by Zygo interferometer. The mask CD change for 88 nm line and space pattern was analyzed using CSM and a CD scanning electron microscope (SEM), and the result shows CD-SEM and CSM give large difference of 3.8 times in mask Delta CD after carbon contamination. This difference confirms the importance of using actinic inspection technique that employs exactly the same imaging condition as exposure tool. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IOP Publishing Ltd | - |
| dc.title | Effect on Critical Dimension Performance for Carbon Contamination of Extreme Ultraviolet Mask Using Coherent Scattering Microscopy and In-situ Contamination System | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1143/JJAP.51.06FB04 | - |
| dc.identifier.scopusid | 2-s2.0-84863335173 | - |
| dc.identifier.wosid | 000306189800005 | - |
| dc.identifier.bibliographicCitation | Japanese Journal of Applied Physics, v.51, no.6, pp 1 - 6 | - |
| dc.citation.title | Japanese Journal of Applied Physics | - |
| dc.citation.volume | 51 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 6 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
| dc.subject.keywordPlus | CD PERFORMANCE | - |
| dc.subject.keywordPlus | EUV MASK | - |
| dc.subject.keywordPlus | LITHOGRAPHY | - |
| dc.subject.keywordPlus | RECONSTRUCTION | - |
| dc.subject.keywordPlus | MODULUS | - |
| dc.subject.keywordPlus | OBJECT | - |
| dc.identifier.url | https://iopscience.iop.org/article/10.1143/JJAP.51.06FB04 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
