Cited 0 time in
Characteristics of a Micro-pattern Gas Detector with Pixel Read-out for X-ray Imaging
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Dong Hoon | - |
| dc.contributor.author | Kim, Bonghoe | - |
| dc.contributor.author | Jeon, Sungchae | - |
| dc.contributor.author | Shin, Ki Young | - |
| dc.contributor.author | Cha, Bokyung | - |
| dc.contributor.author | Seo, Changwoo | - |
| dc.contributor.author | Kim, Yong Kyun | - |
| dc.date.accessioned | 2022-07-16T17:55:53Z | - |
| dc.date.available | 2022-07-16T17:55:53Z | - |
| dc.date.issued | 2011-12 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/167007 | - |
| dc.description.abstract | A micro-pattern gas detector (MPGD) with a pixel read out was evaluated for X-ray imaging. Our MPGD has one gas electron multiplier (GEM) with an active area of 5 x 5 cm(2) as a charge amplifying stage that is completely decoupled from the readout electrode, and we have used an advanced printed-circuit board (PCB) technique to fabricate the micro-pattern readout. A test chamber was fabricated for our experiment, and all components of our MPGD were assembled in a test chamber filled gas. We studied the charge signal by X-ray used for a medical diagnostic system in the pixel readout with a gas mixtures of Xe (90%)/CO(2) (10%) and the performance of our MPGD was examined with an X-ray energy and various applied voltages of the GEM and the drift plate. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Characteristics of a Micro-pattern Gas Detector with Pixel Read-out for X-ray Imaging | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.59.3666 | - |
| dc.identifier.scopusid | 2-s2.0-83455200264 | - |
| dc.identifier.wosid | 000298198500048 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.59, no.6, pp 3666 - 3669 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 59 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 3666 | - |
| dc.citation.endPage | 3669 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001609972 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordAuthor | Micro-pattern gas detector | - |
| dc.subject.keywordAuthor | GEM | - |
| dc.subject.keywordAuthor | X-ray imaging | - |
| dc.identifier.url | https://www.jkps.or.kr/journal/view.html?volume=59&number=6(1)&spage=3666&year=2011 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.