Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Energy Spectrum Improvement with a CZT Strip Detector

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Se-Hwan-
dc.contributor.authorKim, Han Soo-
dc.contributor.authorHa, Jang Ho-
dc.contributor.authorShin, Hee-Sung-
dc.contributor.authorKim, Young Soo-
dc.contributor.authorKim, Ho-Dong-
dc.contributor.authorCho, Yun-Ho-
dc.contributor.authorKim, Yong Kyun-
dc.date.accessioned2022-07-16T19:12:37Z-
dc.date.available2022-07-16T19:12:37Z-
dc.date.issued2011-09-
dc.identifier.issn0374-4884-
dc.identifier.issn1976-8524-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/167677-
dc.description.abstractCadmium zinc telluride (CZT) has been shown to be suitable for use in high-resolution gamma-ray energy spectroscopy and radiation imaging. A low-energy tail appears in the energy spectrum when the high-energy gamma-ray energy spectrum is obtained with a CZT planar detector. This is due to the low charge transport in the crystal. In this study, a CZT detector with strip electrodes was fabricated to reduce the low-energy tail in the energy spectrum. CZT strip detectors with various electrode designs were fabricated, and their operation properties were determined and compared. The optimized detector had the following electrode design: an electrode pitch of 1.2 mm, an electrode width of 0.8 mm and a spacing between the electrodes of 0.4 mm. gamma-ray energy spectra were measured for energies in the range of 60 - 660 keV. The low-energy tail in the spectrum was reduced significantly when the CZT strip detector was used.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisher한국물리학회-
dc.titleEnergy Spectrum Improvement with a CZT Strip Detector-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3938/jkps.59.2237-
dc.identifier.scopusid2-s2.0-80052911785-
dc.identifier.wosid000294971600011-
dc.identifier.bibliographicCitationJournal of the Korean Physical Society, v.59, no.3, pp 2237 - 2240-
dc.citation.titleJournal of the Korean Physical Society-
dc.citation.volume59-
dc.citation.number3-
dc.citation.startPage2237-
dc.citation.endPage2240-
dc.type.docTypeArticle-
dc.identifier.kciidART001586527-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusGAMMA-RAY DETECTORS-
dc.subject.keywordPlusCDZNTE-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordAuthorCZT-
dc.subject.keywordAuthorPlanar detector-
dc.subject.keywordAuthorStrip electrode-
dc.subject.keywordAuthorLow-energy tail-
dc.identifier.urlhttps://www.jkps.or.kr/journal/view.html?volume=59&number=3&spage=2237&year=2011-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE