Cited 0 time in
Comparison to Images from a Computed Radiography System for Non-destructive Testing Using Selenium-75, Iridium-192, and X-rays
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Sang Mook | - |
| dc.contributor.author | Shin, Chang-Ho | - |
| dc.contributor.author | Pham Nhu Viet Ha | - |
| dc.contributor.author | Choi, Chang Il | - |
| dc.contributor.author | Kim, Jong Kyung | - |
| dc.contributor.author | Kim, Yong Kyun | - |
| dc.date.accessioned | 2022-07-16T19:29:20Z | - |
| dc.date.available | 2022-07-16T19:29:20Z | - |
| dc.date.issued | 2011-08 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/167862 | - |
| dc.description.abstract | A computed radiography (CR) system using reusable image plates (IPs) offers a convenient and reliable way to replace a conventional film-screen system for non-destructive testing field. The ability of radiography to detect a defect in welded objects depends on the procedure and embraces several factors such as the measurement conditions, the image plate type/class, the radiation energy, the radiation type, and the source-to-image plate distance. Also, the ability of images to detect a flaw decreases with increasing object thickness. In the study, images of welded objects were acquired with a CR system manufactured by FUJI by using selenium-75, iridium-192, and X-ray with and were obtained through MCNP5 simulations under the same conditions as the given experiments conditions. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Comparison to Images from a Computed Radiography System for Non-destructive Testing Using Selenium-75, Iridium-192, and X-rays | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.59.717 | - |
| dc.identifier.scopusid | 2-s2.0-79961224633 | - |
| dc.identifier.wosid | 000294079700042 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.59, no.2, pp 717 - 720 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 59 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 717 | - |
| dc.citation.endPage | 720 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001575991 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordAuthor | Computed radiography | - |
| dc.subject.keywordAuthor | Image plate | - |
| dc.subject.keywordAuthor | Non-destructive testing | - |
| dc.subject.keywordAuthor | Selenium-75 | - |
| dc.subject.keywordAuthor | MCNP | - |
| dc.identifier.url | https://www.jkps.or.kr/journal/view.html?volume=59&number=2(2)&spage=717&year=2011 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.