Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

DEVELOPMENT AND EVALUATION OF A PHANTOM FOR MULTI-PURPOSE DOSIMETRY IN INTENSITY-MODULATED RADIATION THERAPYopen access

Authors
Jeong, Hae SunHan, YoungyihKum, OyeonKim, Chan HyeongPark, Joo Hwan
Issue Date
Aug-2011
Publisher
KOREAN NUCLEAR SOC
Keywords
IMRT; Phantom; Dosimetry; Heterogeneity
Citation
NUCLEAR ENGINEERING AND TECHNOLOGY, v.43, no.4, pp.399 - 404
Indexed
SCIE
SCOPUS
KCI
Journal Title
NUCLEAR ENGINEERING AND TECHNOLOGY
Volume
43
Number
4
Start Page
399
End Page
404
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/167882
DOI
10.5516/NET.2011.43.4.399
ISSN
1738-5733
Abstract
A LEGO-type multi-purpose dosimetry phantom was developed for intensity-modulated radiation therapy (IMRT), which requires various types of challenging dosimetry. Polystyrene, polyethylene, polytetrafluoroethylene (PTFE), and polyurethane foam (PU-F) were selected to represent muscle, fat, bone, and lung tissue, respectively, after considering the relevant mass densities, elemental compositions, effective atomic numbers, and photon interaction coefficients. The phantom, which is composed of numerous small pieces that are similar to LEGO blocks, provides dose and dose distribution measurements in homogeneous and heterogeneous media. The phantom includes dosimeter holders for several types of dosimeters that are frequently used in IMRT dosimetry. An ion chamber and a diode detector were used to test dosimetry in heterogeneous media under radiation fields of various sizes. The data that were measured using these dosimeters were in disagreement when the field sizes were smaller than 1.5 x 1.5 cm(2) for polystyrene and PTFE, or smaller than 3 x 3 cm(2) for an air cavity. The discrepancy was as large as 41% for the air cavity when the field size was 0.7 x 0.7 cm(2), highlighting one of the challenges of IMRT small field dosimetry. The LEGO-type phantom is also very useful for two-dimensional dosimetry analysis, which elucidates the electronic dis-equilibrium phenomena on or near the heterogeneity boundaries.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE