Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Carbon Contamination Analysis and Its Effect on Extreme Ultra Violet Mask Imaging Performance Using Coherent Scattering Microscopy/In-Situ Accelerated Contamination System

Authors
Jeong, Chang YoungLee, SangsulDoh, Jong GulLee, Jae UkCha, Han-sunNichols, William T.Lee, Dong GunKim, Seong SueCho, Han KuRah, Seung-yuAhn, Jinho
Issue Date
Jul-2011
Publisher
AMER SCIENTIFIC PUBLISHERS
Keywords
EUVL; CSM; Carbon Contamination; Imaging Property; Reflectivity
Citation
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, v.11, no.7, pp.5717 - 5722
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY
Volume
11
Number
7
Start Page
5717
End Page
5722
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168083
DOI
10.1166/jnn.2011.4361
ISSN
1533-4880
Abstract
The coherent scattering microscopy/in-situ accelerated contamination system (CSM/ICS) is a developmental metrology tool designed to analyze the impact of carbon contamination on the imaging performance. It was installed at 11B EUVL beam-line of the Pohang Accelerator Laboratory (PAL). Monochromatized 13.5 nm wavelength beam with Mo/Si multilayer mirrors and zirconium filters was used. The CSM/ICS is composed of the CSM for measuring imaging properties and the ICS for implementing acceleration of carbon contamination. The CSM has been proposed as an actinic inspection technique that records the coherent diffraction pattern from the EUV mask and reconstructs its aerial image using a phase retrieval algorithm. To improve the CSM measurement accuracy, optical and electrical noises of main chamber were minimized. The background noise level measured by CCD camera was similar to 8.5 counts (3 sigma) when the EUV beam was off. Actinic CD measurement repeatability was <1 angstrom (3 sigma) at 17.5 nm line and space pattern. The influence of carbon contamination on the imaging properties can be analyzed by transferring EUV mask to CSM imaging center position after executing carbon contamination without a fine alignment system. We also installed photodiode and ellipsometry for in-situ reflectivity and thickness measurement. This paper describes optical design and system performance observed during the first phase of integration, including CSM imaging performance and carbon contamination analysis results.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 신소재공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Jinho photo

Ahn, Jinho
COLLEGE OF ENGINEERING (SCHOOL OF MATERIALS SCIENCE AND ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE