Cited 0 time in
Determination of metastable level densities in a low-pressure inductively coupled argon plasma by the line-ratio method of optical emission spectroscopy
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Young-Kwang | - |
| dc.contributor.author | Moon, Se-Youn | - |
| dc.contributor.author | Oh, Se-Jin | - |
| dc.contributor.author | Chung, Chin-Wook | - |
| dc.date.accessioned | 2022-07-16T20:00:14Z | - |
| dc.date.available | 2022-07-16T20:00:14Z | - |
| dc.date.issued | 2011-07 | - |
| dc.identifier.issn | 0022-3727 | - |
| dc.identifier.issn | 1361-6463 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168096 | - |
| dc.description.abstract | The line-ratio method of optical emission spectroscopy (OES) is used for the diagnosis of plasma parameters. In this work, electrostatic probe-assisted OES is employed to measure metastable level densities from spectral lines and electron energy distribution functions (EEDFs) in a low-pressure inductively coupled argon plasma. Emission spectroscopy is based on plasma modelling through a simple collisional-radiative model. The line intensities of Ar(3p(5)4p -> 3p(5)4s) are modified due to the plasma reabsorption at relatively high pressures where the plasma becomes optically thick. To consider this effect, a pressure dependence factor alpha(ij) (P) is first derived from both the measured intensity and pressure-dependent cross-section for electron excitation. It is found that the obtained metastable densities range from 1.3 x 10(9) to 1.2 x 10(10) cm(-3) and their ratios are nearly constant by a factor of about 3-5 in the investigated pressure range (3-50m Torr). The effect of non-Maxwellian EEDF on the metastable densities is also discussed. The results measured by the line-ratio method are consistent with that of the OES-branching fraction method taking into account the photon escape factor to treat the radiation trapping. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IOP Publishing Ltd. | - |
| dc.title | Determination of metastable level densities in a low-pressure inductively coupled argon plasma by the line-ratio method of optical emission spectroscopy | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1088/0022-3727/44/28/285203 | - |
| dc.identifier.scopusid | 2-s2.0-79960266273 | - |
| dc.identifier.wosid | 000292090400007 | - |
| dc.identifier.bibliographicCitation | Journal of Physics D: Applied Physics, v.44, no.28, pp 1 - 8 | - |
| dc.citation.title | Journal of Physics D: Applied Physics | - |
| dc.citation.volume | 44 | - |
| dc.citation.number | 28 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 8 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
| dc.subject.keywordPlus | ELECTRON-IMPACT EXCITATION | - |
| dc.subject.keywordPlus | ENERGY DISTRIBUTION FUNCTION | - |
| dc.subject.keywordPlus | CROSS-SECTIONS | - |
| dc.subject.keywordPlus | RARE-GASES | - |
| dc.subject.keywordPlus | TEMPERATURE | - |
| dc.subject.keywordPlus | IONIZATION | - |
| dc.subject.keywordPlus | DISCHARGE | - |
| dc.subject.keywordPlus | ATOMS | - |
| dc.subject.keywordPlus | PARAMETERS | - |
| dc.subject.keywordPlus | 3P(5)4S | - |
| dc.identifier.url | https://iopscience.iop.org/article/10.1088/0022-3727/44/28/285203 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
