External cross-validation of bioelectrical impedance analysis for the assessment of body composition in Korean adults
- Authors
- Kim, Hyeoijin; Kim, Chul-Hyun; Kim, Dong-Won; Park, Mira; Park, Hye Soon; Min, Sun-Seek; Han, Seung-Ho; Yee, Jae-Yong; Chung, Sochung; Kim, Chan
- Issue Date
- Jun-2011
- Publisher
- 한국영양학회
- Keywords
- Body composition; bioelectrical impedance analysis; cross-validation; Dual Energy X-ray Absorptiometry
- Citation
- Nutrition Research and Practice, v.5, no.3, pp 246 - 252
- Pages
- 7
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- Nutrition Research and Practice
- Volume
- 5
- Number
- 3
- Start Page
- 246
- End Page
- 252
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168365
- DOI
- 10.4162/nrp.2011.5.3.246
- ISSN
- 1976-1457
2005-6168
- Abstract
- Bioelectrical impedance analysis (BIA) models must be validated against a reference method in a representative population sample before they can be accepted as accurate and applicable. The purpose of this study was to compare the eight-electrode BIA method with DEXA as a reference method in the assessment of body composition in Korean adults and to investigate the predictive accuracy and applicability of the eight-electrode BIA model. A total of 174 apparently healthy adults participated. The study was designed as a cross-sectional study. FM, %fat, and FFM were estimated by an eight-electrode BIA model and were measured by DEXA. Correlations between BIA_%fat and DEXA_%fat were 0.956 for men and 0.960 for women with a total error of 2.1%fat in men and 2.3%fat in women. The mean difference between BIA_%fat and DEXA_%fat was small but significant (P<0.05), which resulted in an overestimation of 1.2 +/- 2.2%fat (95% CI: -3.2-6.2%fat) in men and an underestimation of -2.0 +/- 2.4%fat (95% CI: -2.3-7.1%fat) in women. In the Bland-Altman analysis, the %fat of 86.3% of men was accurately estimated and the %fat of 66.0% of women was accurately estimated to within 3.5%fat. The BR had good agreement for prediction of %fat in Korean adults. However, the eight-electrode BIA had small, but systemic, errors of %fat in the predictive accuracy for individual estimation. The total errors led to an overestimation of %fat in lean men and an underestimation of %fat in obese women.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.