Cited 0 time in
Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS)
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Chang, Jung Min | - |
| dc.contributor.author | Moon, Woo Kyung | - |
| dc.contributor.author | Cho, Nariya | - |
| dc.contributor.author | Park, Jeong Seon | - |
| dc.contributor.author | Kim, Seung Ja | - |
| dc.date.accessioned | 2022-07-16T21:14:45Z | - |
| dc.date.available | 2022-07-16T21:14:45Z | - |
| dc.date.issued | 2011-04 | - |
| dc.identifier.issn | 0720-048X | - |
| dc.identifier.issn | 1872-7727 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168734 | - |
| dc.description.abstract | Objectives: To retrospectively evaluate the detection performance of benign and malignant breast masses using 3D volume data obtained by ABUS and to determine lesion variables which affect detectability. Methods: Between November and December of 2007, bilateral whole breast US images were obtained using ABUS in 67 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses. Twenty-four invasive ductal cancers in 23 breasts, 46 benign breast lesions in 44 breasts and 38 normal breasts were included. Three breast radiologists (experience range, 8-16 years) who did not perform the examinations and were blinded to the histology independently reviewed the ABUS data of the 105 breasts to detect suspicious solid masses with pathology as the standard of reference. Sensitivity and specificity in detecting benign and malignant masses were calculated, and lesion characteristics affecting detectability were analyzed. Results: Sensitivities for benign and malignant mass detections were 65.2% (30/46), 95.8% (23/24) for reader 1 (p = 0.007), 66.7% (31/46), 87.5% (21/24) for reader 2 (p = 0.087), and 56.3% (24/46), 91.7% (22/24), for reader 3 (p = 0.001), respectively. Logistic analysis showed that mass size (odds ratio, 95% CI; 1.12, 1.02-1.24), surrounding tissue changes (odds ratio, 95% CI; 0.11, 0.02-0.47), and shape of the mass (odds ratio, 95% CI; 3.12, 1.02-9.55) were the variables associated with detectability at ABUS. Conclusion: In reader studies using ABUS data, significantly higher sensitivity was noted for malignant breast masses than for benign masses. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS) | - |
| dc.type | Article | - |
| dc.publisher.location | 아일랜드 | - |
| dc.identifier.doi | 10.1016/j.ejrad.2011.01.074 | - |
| dc.identifier.scopusid | 2-s2.0-79954662331 | - |
| dc.identifier.wosid | 000289558000015 | - |
| dc.identifier.bibliographicCitation | European Journal of Radiology, v.78, no.1, pp 99 - 103 | - |
| dc.citation.title | European Journal of Radiology | - |
| dc.citation.volume | 78 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 99 | - |
| dc.citation.endPage | 103 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | PHYSICAL-EXAMINATION | - |
| dc.subject.keywordPlus | MAMMOGRAPHY | - |
| dc.subject.keywordPlus | CANCER | - |
| dc.subject.keywordPlus | US | - |
| dc.subject.keywordPlus | SONOGRAPHY | - |
| dc.subject.keywordPlus | CARCINOMA | - |
| dc.subject.keywordPlus | LESIONS | - |
| dc.subject.keywordPlus | WORK | - |
| dc.subject.keywordAuthor | Automated breast US | - |
| dc.subject.keywordAuthor | Hand-held ultrasound | - |
| dc.subject.keywordAuthor | Screen US | - |
| dc.subject.keywordAuthor | Detection performance | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0720048X11001136?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.