Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS)

Authors
Chang, Jung MinMoon, Woo KyungCho, NariyaPark, Jeong SeonKim, Seung Ja
Issue Date
Apr-2011
Publisher
ELSEVIER IRELAND LTD
Keywords
Automated breast US; Hand-held ultrasound; Screen US; Detection performance
Citation
EUROPEAN JOURNAL OF RADIOLOGY, v.78, no.1, pp.99 - 103
Indexed
SCIE
SCOPUS
Journal Title
EUROPEAN JOURNAL OF RADIOLOGY
Volume
78
Number
1
Start Page
99
End Page
103
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168734
DOI
10.1016/j.ejrad.2011.01.074
ISSN
0720-048X
Abstract
Objectives: To retrospectively evaluate the detection performance of benign and malignant breast masses using 3D volume data obtained by ABUS and to determine lesion variables which affect detectability. Methods: Between November and December of 2007, bilateral whole breast US images were obtained using ABUS in 67 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses. Twenty-four invasive ductal cancers in 23 breasts, 46 benign breast lesions in 44 breasts and 38 normal breasts were included. Three breast radiologists (experience range, 8-16 years) who did not perform the examinations and were blinded to the histology independently reviewed the ABUS data of the 105 breasts to detect suspicious solid masses with pathology as the standard of reference. Sensitivity and specificity in detecting benign and malignant masses were calculated, and lesion characteristics affecting detectability were analyzed. Results: Sensitivities for benign and malignant mass detections were 65.2% (30/46), 95.8% (23/24) for reader 1 (p = 0.007), 66.7% (31/46), 87.5% (21/24) for reader 2 (p = 0.087), and 56.3% (24/46), 91.7% (22/24), for reader 3 (p = 0.001), respectively. Logistic analysis showed that mass size (odds ratio, 95% CI; 1.12, 1.02-1.24), surrounding tissue changes (odds ratio, 95% CI; 0.11, 0.02-0.47), and shape of the mass (odds ratio, 95% CI; 3.12, 1.02-9.55) were the variables associated with detectability at ABUS. Conclusion: In reader studies using ABUS data, significantly higher sensitivity was noted for malignant breast masses than for benign masses.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jeong Seon photo

Park, Jeong Seon
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE