강교용 박스거더의 용접예열 온도 선정에 관한 연구Determination of Preheating Temperature for Box Girder Welding
- Other Titles
- Determination of Preheating Temperature for Box Girder Welding
- Authors
- 조재훈; 문승재; 유호선
- Issue Date
- Mar-2011
- Publisher
- 한국플랜트학회
- Keywords
- box girder; carbon equivalent; preheating; welding crack
- Citation
- 플랜트 저널, v.7, no.1, pp.49 - 55
- Indexed
- OTHER
- Journal Title
- 플랜트 저널
- Volume
- 7
- Number
- 1
- Start Page
- 49
- End Page
- 55
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168791
- ISSN
- 1739-7200
- Abstract
- This study analyzed causes and status of cracks to suggest preventives for welding cracks generated on fillet welding zone of atmosphere corrosion resisting steel box girder. Penetrant testing, a sort of non-destructive testing, was conducted for inspection of crack status on welding zone. As a result of test, welding cracks were found on the point of start, center and end to fillet welding zone of 32 mm-thickness. The result of carbon equivalent composition of materials was 0.452%. According to welding specification, to preheat prevent welding crack, preheat temperature of 100∼200∘C should be kept before welding execution. It was failed to keep preheat temperature because it had been executed on winter season and the structure of box girder had wide heat transfer area. As a result of examination of time varying preheating temperature of 32mm-thickness material, it was understood that preheat temperature of above 230∘C on both 130mm-long sides of welded joint can prevent welding crack.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > 서울 기계공학부 > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.