Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

산소주입 수처리 발전소용 급수펌프 밀봉장치의 누설방지Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment

Other Titles
Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment
Authors
신정국문승재유호선
Issue Date
Mar-2011
Publisher
한국플랜트학회
Keywords
oxygen treatment; mechanical seal; corrosion of antimony
Citation
플랜트 저널, v.7, no.1, pp.56 - 63
Indexed
OTHER
Journal Title
플랜트 저널
Volume
7
Number
1
Start Page
56
End Page
63
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168792
ISSN
1739-7200
Abstract
The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Seung Jae photo

Moon, Seung Jae
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE