Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Validation of the Lower Limit of Normal Diffusing Capacity for Detecting Emphysema

Authors
Lee, Jae SeungRa, Seung WonChae, Eun JinSeo, Joon BeomLim, Seong YongKim, Tae-HyungLee, Sang-DoOh, Yeon-Mok
Issue Date
Mar-2011
Publisher
KARGER
Keywords
Validation; Lower limit of normal; Diffusing capacity; Emphysema; Chronic obstructive pulmonary disease
Citation
RESPIRATION, v.81, no.4, pp.287 - 293
Indexed
SCIE
SCOPUS
Journal Title
RESPIRATION
Volume
81
Number
4
Start Page
287
End Page
293
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168953
DOI
10.1159/000279757
ISSN
0025-7931
Abstract
Background: Diffusing capacity for carbon monoxide (D-Lco) has been regarded as reliable for detecting emphysema. The lower 5th percentile of the reference population has been used as the lower limit of normal (LLN) for D-Lco, without clinical validation. Objectives: We performed this study to validate the LLN for D-Lco and to determine the optimum cutoff LLN value for detecting emphysema. Methods: A total of 197 COPD patients and 103 healthy adult subjects were included. COPD patients with emphysema were defined as COPD patients in whom volumetric CT showed that the volume fraction of the lung at less than -950 Hounsfield units at full inspiration was more than 15%. All other COPD patients were defined as COPD patients without emphysema. All measured D-Lco values were transformed to estimates of refer ence population percentiles. ROC curve analysis was used to validate and to determine the optimum cutoff percentile value as the LLN for D-Lco. Results: Of the 197 COPD patients, 126 were classified as having emphysema and 71 as without emphysema. On ROC curve analysis, the lower 5th percentile used as the LLN for D-Lco had a sensitivity of 68.3% and a specificity of 98.1% to differentiate COPD patients with emphysema from healthy subjects. The lower 9th percentile was the best LLN cutoff value for detecting COPD patients with emphysema. Conclusion: The lower 5th percentile of the reference population may not be the best LLN cutoff value for D-Lco for detecting emphysema.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae Hyung photo

Kim, Tae Hyung
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE