Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Importance of channel dimension for flow-electrode flowing in flow-electrode capacitive mixing (F-CapMix): Evaluation of net power density under high-pressure-drop conditions

Authors
Kim, DonghyunKwon, HwabhinCho, Geun-HoKim, HaeunSeo, HaeunJung, Yeon-GilChoi, JiyeonKim, HankiYoo, JungjoonLee, DongsooHwang, InsungPaik, UngyuSong, TaeseupPark, HeesungYang, SeungCheol
Issue Date
Jun-2022
Publisher
Elsevier B.V.
Keywords
Capacitive mixing; Flow-electrode; Flow channel; Pressure drop; Net power
Citation
Separation and Purification Technology, v.290, pp.1 - 10
Indexed
SCIE
SCOPUS
Journal Title
Separation and Purification Technology
Volume
290
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/170131
DOI
10.1016/j.seppur.2022.120859
ISSN
1383-5866
Abstract
Flow-electrode capacitive mixing (F-CapMix) utilizes ion adsorption/desorption on active materials in the flow-electrode to harvest salinity gradient power. In order to facilitate flow-electrode flow in the F-CapMix unit cell, the current collectors should include a meandering flow channel for the cell assembly and should facilitate efficient electron transport between them and the flow-electrode active materials. This study evaluates the F-CapMix performance variation and pumping power of the flow-electrode and feed water depending on flow channel depth. It was found that both parameters increased as the cross-sectional area of the flow channel narrowed. This result was due to the increasing linear velocity of the flow-electrode, which itself was associated with the narrowing cross-sectional area. The maximum gross power densities of the F-CapMix increased in a parabolic shape with respect to the flow-electrode linear velocity increase. (0.68 → 0.83 → 0.86 → 1.03 → 1.14 W/m2) On the contrary, pumping power densities of the flow-electrode increased linearly (2.22 → 2.98 → 3.51 → 5.93 → 19.67 W/m2) with linear velocity increment of the flow-electrode. Further, the F-CapMix net power density was negatively affected by the increasing linear velocity of the flow-electrode (net power density variation from −2.06 to −19.10 W/m2), likely owing to the higher pumping power density required due to the narrower flow channel. This study verifies the importance of securing an appropriate cross-sectional area of the meandering flow channel to maintain positive net power of the F-CapMix.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 에너지공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Paik, Ungyu photo

Paik, Ungyu
COLLEGE OF ENGINEERING (DEPARTMENT OF ENERGY ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE