Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Objective Interpretation of the Rapid Urease Test for Helicobacter pylori Infection Using Colorimetryopen access

Authors
Pih, Gyu YoungNoh, Jin HeeAhn, Ji YongHan, Gill SangJung, Hyun SukJung, Hwoon-YongKim, Jung Mogg
Issue Date
Jul-2022
Publisher
KOREAN ACAD MEDICAL SCIENCES
Keywords
Helicobacter pylori; Rapid Urease Test; Diagnosis; Spectrophotometer
Citation
JOURNAL OF KOREAN MEDICAL SCIENCE, v.37, no.29, pp.1 - 7
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF KOREAN MEDICAL SCIENCE
Volume
37
Number
29
Start Page
1
End Page
7
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/171567
DOI
10.3346/jkms.2022.37.e227
ISSN
1011-8934
Abstract
Background: The rapid urease test (RUT) is a major diagnostic tool for detecting Helicobacter pylori infection. This study aimed to establish an objective method for measuring the color changes in the RUT kit to improve the test???s diagnostic accuracy. Methods: A UV-visible spectrophotometer was selected as the colorimeter; experiments were conducted in three stages to objectively identify the color changes in the RUT kit. Results: First, the urea broth solution showed an identifiable color change from yellow to red as the pH increased by 0.2. The largest transmittance difference detected using the UV-visible spectrophotometer was observed at a 590-nm wavelength. Second, the commercialized RUT kit also showed a gradual color change according to the pH change detected using the UV-visible spectrophotometer. Third, 13 cases of negative RUT results with a biopsy specimen and 16 of positive RUT results were collected. The transmittance detected using the UV-visible spectrophotometer showed a clear division between the positive and negative RUT groups; the largest difference was observed at a 559-nm wavelength. The lowest transmittance in the negative RUT group was 64, while the highest in the positive RUT group was 56, at the 559-nm wavelength. The UV-visible spectrophotometry reading showed a consistency of 92.7% compared with that of manual reading. Conclusion: A transmittance of 60 at a 559-nm wavelength detected using UV-visible spectrophotometer can be used as a cutoff value for interpreting RUT results; this will help develop an automatic RUT kit reader with a high accuracy.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 미생물학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jung Mogg photo

Kim, Jung Mogg
COLLEGE OF MEDICINE (DEPARTMENT OF MEDICAL MICROBIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE