A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Han Soo-
dc.contributor.authorHa, Jang Ho-
dc.contributor.authorPark, Se-Hwan-
dc.contributor.authorKim, Jung Bok-
dc.contributor.authorKim, Yong Kyun-
dc.contributor.authorJin, Hyung-Ho-
dc.date.accessioned2022-10-07T09:39:05Z-
dc.date.available2022-10-07T09:39:05Z-
dc.date.issued2009-06-
dc.identifier.issn2508-1888-
dc.identifier.issn2466-2461-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/171722-
dc.description.abstractAn Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 μR/h and 2.9 μR/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisher대한방사선방어학회-
dc.titleA LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation방사선방어학회지, v.34, no.2, pp 77 - 81-
dc.citation.title방사선방어학회지-
dc.citation.volume34-
dc.citation.number2-
dc.citation.startPage77-
dc.citation.endPage81-
dc.identifier.kciidART001352963-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthorARMS (Area Radiation Monitoring System)-
dc.subject.keywordAuthorIonization Chamber-
dc.subject.keywordAuthorLong-term Stability-
dc.subject.keywordAuthorLinearity-
dc.subject.keywordAuthorNuclear Power Plant-
dc.identifier.urlhttps://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200921140047917&SITE=CLICK-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE