| dc.description.abstract | An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 μR/h and 2.9 μR/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한방사선방어학회 | - |
| dc.title | A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 방사선방어학회지, v.34, no.2, pp 77 - 81 | - |
| dc.citation.title | 방사선방어학회지 | - |
| dc.citation.volume | 34 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 77 | - |
| dc.citation.endPage | 81 | - |
| dc.identifier.kciid | ART001352963 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kciCandi | - |
| dc.subject.keywordAuthor | ARMS (Area Radiation Monitoring System) | - |
| dc.subject.keywordAuthor | Ionization Chamber | - |
| dc.subject.keywordAuthor | Long-term Stability | - |
| dc.subject.keywordAuthor | Linearity | - |
| dc.subject.keywordAuthor | Nuclear Power Plant | - |
| dc.identifier.url | https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200921140047917&SITE=CLICK | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.