Development and validation of reverberation-chamber type whole-body exposure system for mobile-phone frequency

Authors
Jung, Keun BumKim, Tea-HongKim, J. L.Doh, Hea-JeongChung, Yeon-ChoonChoi, Jae HoonPack, Jeong-Ki
Issue Date
Mar-2008
Publisher
INFORMA HEALTHCARE
Keywords
exposure system; reverberation chamber; FDTD; SAR
Citation
ELECTROMAGNETIC BIOLOGY AND MEDICINE, v.27, no.1, pp.73 - 82
Indexed
SCIE
SCOPUS
Journal Title
ELECTROMAGNETIC BIOLOGY AND MEDICINE
Volume
27
Number
1
Start Page
73
End Page
82
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172112
DOI
10.1080/15368370701878895
ISSN
1536-8378
Abstract
We developed whole-body exposure systems for in-vivo study at cellular (848.5 MHz) and Personal Communication System (PCS, 1,762.5 MHz) frequency, utilizing reverberation chamber. The field uniformities in the test area of the designed chambers were verified by simulation and measurement. In the whole-body exposure environment, Specific Absorption Rate (SAR) distributions inside of mice were calculated using Finite Difference Time Domain (FDTD) simulation. Key results are presented in this article.