Development and validation of reverberation-chamber type whole-body exposure system for mobile-phone frequency
- Authors
- Jung, Keun Bum; Kim, Tea-Hong; Kim, J. L.; Doh, Hea-Jeong; Chung, Yeon-Choon; Choi, Jae Hoon; Pack, Jeong-Ki
- Issue Date
- Mar-2008
- Publisher
- Marcel Dekker Inc.
- Keywords
- exposure system; reverberation chamber; FDTD; SAR
- Citation
- Electromagnetic Biology and Medicine, v.27, no.1, pp 73 - 82
- Pages
- 10
- Indexed
- SCIE
SCOPUS
- Journal Title
- Electromagnetic Biology and Medicine
- Volume
- 27
- Number
- 1
- Start Page
- 73
- End Page
- 82
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172112
- DOI
- 10.1080/15368370701878895
- ISSN
- 1536-8378
1536-8386
- Abstract
- We developed whole-body exposure systems for in-vivo study at cellular (848.5 MHz) and Personal Communication System (PCS, 1,762.5 MHz) frequency, utilizing reverberation chamber. The field uniformities in the test area of the designed chambers were verified by simulation and measurement. In the whole-body exposure environment, Specific Absorption Rate (SAR) distributions inside of mice were calculated using Finite Difference Time Domain (FDTD) simulation. Key results are presented in this article.
- Files in This Item