Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구

Authors
유성현박원희박주진이영수
Issue Date
May-2006
Publisher
대한치과보철학회
Keywords
Implant prosthesis; Fixture shape; Abutment connection type; Finite element stress analysis; Von mises stress
Citation
대한치과보철학회지, v.44, no.2, pp.207 - 216
Indexed
KCI
Journal Title
대한치과보철학회지
Volume
44
Number
2
Start Page
207
End Page
216
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172462
ISSN
0301-2875
Abstract
Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently, the fixture that has tapered form of internal connection is often selected. However, the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture: Branemark, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analy sis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of Branemark system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than Branemark system.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 치과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Won hee photo

Park, Won hee
COLLEGE OF MEDICINE (DEPARTMENT OF DENTISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE