Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Clinical outcomes of new multifocal intraocular lenses with hydroxyethyl methacrylate and comparative results of contrast sensitivity, objective scatter, and subjective photic phenomenaopen access

Authors
Lee, Yong WooChoi, Chul YoungMoon, KunJeong, Yong JinAn, Sang IlLee, Je MyungLee, Jong HoSeong, Min Cheol
Issue Date
Sep-2022
Publisher
BMC
Keywords
Hydroxyethyl methacrylate; Multifocal intraocular lens; Contrast sensitivity
Citation
BMC OPHTHALMOLOGY, v.22, no.1, pp.1 - 8
Indexed
SCIE
SCOPUS
Journal Title
BMC OPHTHALMOLOGY
Volume
22
Number
1
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172553
DOI
10.1186/s12886-022-02600-x
ISSN
1471-2415
Abstract
Background We investigate the performance of new hydrophobic diffractive multifocal intraocular lenses (IOL) with hydroxyethyl methacrylate (HEMA) and compare their optical quality, contrast sensitivity, and subjective photic phenomena. Methods Medical records of patients who underwent routine simple cataract surgery and insertion of an existing multifocal IOL (TFNT, TF group) or a new multifocal IOL (CNWT, CN group) were retrospectively reviewed. Clinical data was collected 2 months postoperatively and included optical quality analysis system (OQAS) indices, contrast sensitivity, and subjective degrees of photic phenomena. Results One hundred thirty-five eyes of 135 patients were included (CN group, 71; TF group, 64). There was no significant difference between the two groups in the visual acuity and defocus curve. The indices of OQAS did not show a significant difference between groups. Contrast sensitivity was significantly better in the CN group at all degrees, including the area under the log contrast sensitivity function (p = 0.01). The subjective photic phenomena survey showed better results for the CN group, with the proportion of patients reporting no photic phenomena as 9.9% and 3.1% in the CN and TF groups, respectively. The proportion of patients who reported severe photic phenomena was 11.3% in the CN group and 25.0% in the TF group. Although the follow-up period was only 2 months, glistening, surface scattering, and posterior capsule opacity were not observed in any patient. Conclusions The new multifocal IOL with HEMA is safe, and provides stable visual acuity as well as superior contrast sensitivity and lower subjective photic phenomena, over the prior IOL.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE