Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electrically-Small Antenna With Low SAR for Scalp and Deep Tissue Biomedical Devicesopen access

Authors
Shah, Syed Manaf AliZada, MuhammadNasir, JamalOwais, OwaisYoo, Hyoungsuk
Issue Date
Aug-2022
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Communication link; impedance bandwidth; implantable antenna; specific absorption rate; ultra-miniaturized
Citation
IEEE ACCESS, v.10, pp.90971 - 90981
Indexed
SCIE
SCOPUS
Journal Title
IEEE ACCESS
Volume
10
Start Page
90971
End Page
90981
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172597
DOI
10.1109/ACCESS.2022.3201896
ISSN
2169-3536
Abstract
An ultra-miniaturized implantable antenna for scalp and deep tissue implants operating in the Industrial, Scientific, and Medical (ISM) frequency band is proposed in this communication. The proposed antenna has a compact size of only 4.422 mm(3) (3.45 x 3.4 x 0.377 mm(3)). A meandered patch backed by a full ground plane was used to implement the proposed ultra-miniaturized antenna. The full ground plane does not allow backward energy flow, thus ensuring patient safety. The performance of the proposed antenna was evaluated in three different simulation environments: homogeneous skin phantom (HSP), skin implant multilayer phantom (SIMP), and muscle implant multilayer phantom (MIMP) models with and without a dummy implantable wireless device (IMD). These models were considered to evaluate the performance of the proposed antenna in more realistic complex human body environments. The proposed antenna demonstrated excellent impedance matching performance at the ISM band with a measured -10 dB impedance bandwidth of 260 MHz (2,249-2,511 MHz). The effects of coaxial cable on antenna performance were also studied. The proposed antenna exhibited a maximum measured peak gain of -26.54 dBi. Furthermore, the 1-g and 10-g specific absorption rate (SAR) values were calculated and satisfied the safety guidelines. A reliable communication link up to distances of 15, 4, and 1.3m for bit rates of 7 kbps, 100 kbps, and 1 Mbps, respectively, can be established between the implantable device and external base station. Finally, a sensitivity analysis of the proposed antenna was conducted showing that the proposed implantable antenna can efficiently work under varying tissue conditions.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 생체공학전공 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hyoungsuk photo

Yoo, Hyoungsuk
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE