Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Classification of Central Venous Catheter Tip Position on Chest X-ray Using Artificial Intelligenceopen access

Authors
Jung, SeungkyoOh, JaehoonRyu, JongbinKim, JihoonLee, JuncheolCho, YongilYoon, Myeong SeongJeong, Ji Young
Issue Date
Oct-2022
Publisher
MDPI
Keywords
image; central venous catheter; deep learning; machine learning; artificial intelligence; AI
Citation
JOURNAL OF PERSONALIZED MEDICINE, v.12, no.10, pp.1 - 9
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PERSONALIZED MEDICINE
Volume
12
Number
10
Start Page
1
End Page
9
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172955
DOI
10.3390/jpm12101637
ISSN
2075-4426
Abstract
Recent studies utilizing deep convolutional neural networks (CNN) have described the central venous catheter (CVC) on chest radiography images. However, there have been no studies for the classification of the CVC tip position with a definite criterion on the chest radiograph. This study aimed to develop an algorithm for the automatic classification of proper depth with the application of automatic segmentation of the trachea and the CVC on chest radiographs using a deep CNN. This was a retrospective study that used plain chest supine anteroposterior radiographs. The trachea and CVC were segmented on images and three labels (shallow, proper, and deep position) were assigned based on the vertical distance between the tracheal carina and CVC tip. We used a two-stage approach model for the automatic segmentation of the trachea and CVC with U-net(++) and automatic classification of CVC placement with EfficientNet B4. The primary outcome was a successful three-label classification through five-fold validations with segmented images and a test with segmentation-free images. Of a total of 808 images, 207 images were manually segmented and the overall accuracy of the five-fold validation for the classification of three-class labels (mean (SD)) of five-fold validation was 0.76 (0.03). In the test for classification with 601 segmentation-free images, the average accuracy, precision, recall, and F1-score were 0.82, 0.73, 0.73, and 0.73, respectively. We achieved the highest accuracy value of 0.91 in the shallow position label, while the highest F1-score was 0.82 in the deep position label. A deep CNN can achieve a comparative performance in the classification of the CVC position based on the distance from the carina to the CVC tip as well as automatic segmentation of the trachea and CVC on plain chest radiographs.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Yongil photo

Cho, Yongil
COLLEGE OF MEDICINE (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE