후두 레이저 수술 중 내화성 테이프를 이용한 기관 내 튜브의 보호Protection of Endotracheal Tube During Laryngeal Laser Surgery Using Fire Resistant Tape
- Other Titles
- Protection of Endotracheal Tube During Laryngeal Laser Surgery Using Fire Resistant Tape
- Authors
- 고석화; 지용배; 서우근
- Issue Date
- Oct-2022
- Publisher
- 대한이비인후과학회
- Keywords
- Explosions; Larynx; Laser; Laser surgery.
- Citation
- 대한이비인후-두경부외과학회지, v.65, no.10, pp 644 - 647
- Pages
- 4
- Indexed
- SCOPUS
KCI
- Journal Title
- 대한이비인후-두경부외과학회지
- Volume
- 65
- Number
- 10
- Start Page
- 644
- End Page
- 647
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172971
- DOI
- 10.3342/kjorl-hns.2022.00605
- ISSN
- 2092-5859
2092-6529
- Abstract
- Operating-room airway fires are serious and potentially fatal complications. To prevent airwayfire in CO2 laser surgery of the larynx, many techniques and devices have been developed. Usinglaser safe tube is one of the common methods of preventing airway fire, but it is very expansiveand hard to treat. In this study, we used a fire-resistant tape to protect the endotrachealtube and had very successful results in experiments with CO2 laser. In this article, we introducethe technique of using a fire-resistant tape to protect endotracheal tube.