Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Spinal stability analysis of lumbar interbody fusion according to pelvic type and cage angle based on simplified spinal model with various pelvic indicesopen access

Authors
Kim, Cheol-JeongSon, Seung MinChoi, Sung HoonRyu, DongmanLee, Chiseung
Issue Date
Oct-2022
Publisher
FRONTIERS MEDIA SA
Keywords
pelvis index; simplified model; lumbar flexibility; spine stability; finite element analysis; lumbar interbody fusion
Citation
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, v.10, pp.1 - 13
Indexed
SCIE
SCOPUS
Journal Title
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY
Volume
10
Start Page
1
End Page
13
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172995
DOI
10.3389/fbioe.2022.1002276
ISSN
2296-4185
Abstract
Recently, the objectives of lumbar interbody fusion (LIF) have been extended to include the correction of broader/relative indications in addition to spinal fixation. Accordingly, LIF must be optimized for sagittal alignment while simultaneously achieving decompression. Therefore, a representative model classified into three pelvic types, i.e., neutral pelvis (NP), anterior pelvis (AP), and retroverted pelvis (RP), was selected according to the pelvic index, and LIF was performed on each representative model to analyze Lumbar lordosis (LL) and the corresponding equivalent stress. The finite element (FE) model was based on a sagittal 2D X-ray image. The calculation efficiency and convergence were improved by simplifying the modeling of the vertebral body in general and its posterior portion in particular. Based on the position of the pelvis, according to the pelvic shape, images of patients were classified into three types: AP, RP, and NP. Subsequently, representative images were selected for each type. The fixation device used in the fusion model was a pedicle screw and a spinal rod of a general type. PEEK was used as the cage material, and the cage shape was varied by using three different cage angles: 0°, 4°, and 8°. Spinal mobility: The pelvic type with the highest range of motion (ROM) for the spine was the NP type; the AP type had the highest LL. Under a combination load, the NP type exhibited the highest lumbar flexibility (LF), which was 2.46° lower on average compared to the case where a pure moment was applied. Equivalent stress on the spinal fixation device: The equivalent stress acting on the vertebrae was lowest when cage 0 was used for the NP and AP type. For the RP type, the lowest equivalent stress on the vertebrae was observed when cage 4 was used. Finally, for the L5 upper endplate, the stress did not vary significantly for a given type of cage. In conclusion, there was no significant difference in ROM according to cage angle, and the highest ROM, LL and LF were shown in the pelvic shape of NP type. However, when comparing the results with other pelvic types, it was not possible to confirm that LF is completely dependent on LL and ROM.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Sung Hoon photo

Choi, Sung Hoon
COLLEGE OF MEDICINE (DEPARTMENT OF ORTHOPEDIC SURGERY)
Read more

Altmetrics

Total Views & Downloads

BROWSE