Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Point -of -care blood analysis of hypotensive patients in the emergency department*

Authors
Shin, HyungooLee, InhyeKim, Chang sunChoi, Hyuk Joong
Issue Date
Jun-2020
Publisher
W. B. Saunders Co., Ltd.
Keywords
Capillary blood; Emergency medical services; Hypotension; Point-of-care systems
Citation
American Journal of Emergency Medicine, v.38, no.6, pp.1049 - 1057
Indexed
SCIE
SCOPUS
Journal Title
American Journal of Emergency Medicine
Volume
38
Number
6
Start Page
1049
End Page
1057
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/173268
DOI
10.1016/j.ajem.2019.158363
ISSN
0735-6757
Abstract
Objective: The aim of this study is to compare a point -of -care (POC) analysis, Enterprise POC (epoc), using the capillary blood obtained from skin puncture with conventional laboratory tests using arterial and venous blood in hypotensive patients. Methods: This study was conducted at the emergency department of a tertiary care hospital between June and November 2018.231 hypotensive patients were enrolled. Three types of blood samples (capillary blood from skin puncture and arterial and venous blood from blood vessel puncture) were collected and analyzed. We com- pared a total of 13 parameters (pH, pCO2, pO2, HCO3 -, Ca2+, lactate, Na+, K+, Cl -, glucose, Hb, Hct, and cre- atinine) between the POC analysis and reference analyzers by performing the equivalence test and Bland -Altman plot analysis. Results: In hypotensive patients, with the exception of two parameters (pCO2, pO2), the pH, HCO3 -, Ca2+, lac- tate, Na+, K+, Cl -, glucose, Hb, Hct, and creatinine parameters measured by the POC analysis were equivalent to or correlated with the reference values. In the patients with cardiac arrest group, nine parameters (pH, HCO3 -, Ca2+, Na+, K+, glucose, Hb, Hct, and creatinine) analyzed by the epoc system were equivalent to the reference values. Conclusion: Most parameters, except pO2, measured by the epoc system using the capillary blood in hypotensive patients were equivalent to or correlated with those measured by the reference analyzers.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, hyuk joong photo

Choi, hyuk joong
COLLEGE OF MEDICINE (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE