Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Determination of the CD Performance and Carbon Contamination of an EUV Mask by Using a Coherent Scattering Microscopy/In-situ Contamination System

Full metadata record
DC Field Value Language
dc.contributor.authorDoh, Jonggul-
dc.contributor.authorJeong, Chang Young-
dc.contributor.authorLee, Sangsul-
dc.contributor.authorLee, Jae Uk-
dc.contributor.authorCha, Han-Sun-
dc.contributor.authorAhn, Jinho-
dc.contributor.authorLee, Dong Gun-
dc.contributor.authorKim, Seong Sue-
dc.contributor.authorCho, Han Ku-
dc.contributor.authorRah, Seung-yu-
dc.date.accessioned2022-12-20T10:54:27Z-
dc.date.available2022-12-20T10:54:27Z-
dc.date.created2022-08-26-
dc.date.issued2010-12-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/173409-
dc.description.abstractThe impact of carbon contamination on imaging performance was analyzed using an in-situ accelerated contamination system (ICS) combined with coherent scattering microscopy (CSM) at the 11B extreme ultraviolet lithography (EUVL) beamline of the Pohang Accelerator Laboratory (PAL). The CSM/ICS is composed of the CSM for measuring imaging properties and the ICS for accelerating the carbon contamination. The CD (critical dimension) and the reflectivity of the mask were compared before and after carbon contamination through acceleration exposure. The reflectivity degradation was 1.3%, 2.1%, and 2.5% after 1-, 2-, and 3-hour exposures, respectively, due to carbon contamination of 5, 10, and 20 nm as measured by using a Zygo interferometer. The mask CD change of an 88-nm line and space pattern was analyzed using CSM and CD SEM (scanning electron microscope), and the result showed a similar trend, but a different absolute value. This difference confirmed the importance of the actinic inspection technique, which employs exactly the same imaging condition as the exposure tool.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleDetermination of the CD Performance and Carbon Contamination of an EUV Mask by Using a Coherent Scattering Microscopy/In-situ Contamination System-
dc.typeArticle-
dc.contributor.affiliatedAuthorAhn, Jinho-
dc.identifier.doi10.3938/jkps.57.1486-
dc.identifier.scopusid2-s2.0-78650369953-
dc.identifier.wosid000285486100029-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.57, no.6, pp.1486 - 1489-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume57-
dc.citation.number6-
dc.citation.startPage1486-
dc.citation.endPage1489-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001501098-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordAuthorEUVL-
dc.subject.keywordAuthorCSM-
dc.subject.keywordAuthorCarbon contamination-
dc.subject.keywordAuthorMask CD-
dc.subject.keywordAuthorReflectivity-
dc.identifier.urlhttps://www.jkps.or.kr/journal/view.html?volume=57&number=6&spage=1486&year=2010-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 신소재공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Jinho photo

Ahn, Jinho
COLLEGE OF ENGINEERING (SCHOOL OF MATERIALS SCIENCE AND ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE