Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Resolution recoverable statistical listmode reconstruction using depth dependent point spread function for Compton camera

Authors
Kim, Soo MeeLee, Jae SungSeo, HeePark, Jin-HyungKim, Chan HyeongLee, Chun SikLee, Myung ChulLee, Dong SooLee, Soo-Jin
Issue Date
Nov-2010
Publisher
IEEE
Citation
IEEE Nuclear Science Symposium Conference Record, pp.3527 - 3530
Indexed
SCOPUS
Journal Title
IEEE Nuclear Science Symposium Conference Record
Start Page
3527
End Page
3530
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/173446
DOI
10.1109/NSSMIC.2010.5874464
ISSN
1095-7863
Abstract
A Compton camera is an imaging system for three-dimensional (3D) distribution of gamma emitting sources based on Compton scattering interaction. The measurement error on energies and positions directly leads to uncertainties on the formation of cones and degrades the spatial resolution of the reconstructed images. Mostly the limited energy resolution, Doppler broadening and position segmentation of detectors cause angular and positional uncertainties on measurements. Since the conical surfaces are delocalized by angular and positional uncertainties into image space, degradation of spatial resolution may be severe depending on the distance (or depth) from the Compton camera. In order to enhance the deteriorated spatial resolution due to angular and positional uncertainties, this study investigates 3D Gaussian point spread function (PSF) incorporable into listmode ordered subset expectation maximization (LMOSEM) as a part of system matrix. Especially the depth-dependent PSF is applied as resolution recovery (RR) technique by image-space convolution operation. We investigated two different RR approaches: one (denoted by LMOSEM-RR-F) is when the convolution is performed in forward projection step only, and the other (denoted by LMOSEM-RR-FB) is when it is performed in both forward and backward projection steps. Using Monte Carlo data for 7 point sources at different depth from the Compton camera, the fitted axial and radial FWHM functions were obtained as FWHMaxial (i)0.2442i1.054 and FWHMradial (i)0.2369i-1.005, respectively. The simulation results showed that both RR approaches with depth dependent PSF gave an improvement on spatial resolution comparing to LMOSEM without RR techniques. Although LMOSEM-RR-F provided better resolution than LMOSEM-RR-FB, LMOSEM-RR-FB could still be useful for low counting statistics in measurement.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE