Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Current Status of Central Concentrate Delivery System for Hemodialysis in Korea

Authors
Han, Sang-WoongYi, Joo-HarkKim, Ho-Jung
Issue Date
Jun-2009
Publisher
KARGER
Keywords
Dialysate; Central delivery system; Central concentrate delivery system; Hemodialysis; Ozone
Citation
BLOOD PURIFICATION, v.27, pp.70 - 73
Indexed
SCIE
SCOPUS
Journal Title
BLOOD PURIFICATION
Volume
27
Start Page
70
End Page
73
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176654
DOI
10.1159/000213501
ISSN
0253-5068
Abstract
So far, less than 10% of hemodialysis (HD) facilities in Korea have adopted a kind of central delivery system (CDS) for dialysates, the so-called Korean central concentrate delivery system (CCDS). In our CCDS, all concentrate solutions of the acid and bicarbonate dry powder mixed with the treated reverse osmosis (RO) water in the mixing tank and stored in the holding tank are centrally delivered to individual HD machines via two streams along with a one further stream for dilution RO water. This mode of Korean CCDS is different from the central dialysate delivery system (CDDS), which uses already fully proportioned acid and bicarbonate concentrates with dilution RO water delivering it via a single stream. At present, the most popular CCDS in Korea is NephroMix Premium (R), which is an all-in-one system that combines the mixing tank, the holding tank, and the control functions into one unified case. Moreover, all CCDS data can be monitored in real-time through a user-friendly touch-screen panel, and stored on a desktop PC linked to the manufacturer's main office. For the disinfection and sterility of NephroMix Premium (R), ozone is used besides a three-step filtering system for removing endotoxin and microbials. Compared to the conventional system in Korea with individual concentrate delivery to single-patient dialysis machines, the Korean-style CCDS seems to be superb in the way of convenience, environmental friendliness, and economy, and also needs less space in the dialysis unit. However, full proof of its safety and effectiveness is required for further verification in the future.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang-Woong photo

Han, Sang-Woong
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE