일측 폐환기 시 용적조절환기와 압력조절환기의 비교Comparison of volume-control and pressure-control ventilation during one-lung ventilation

Other Titles
Comparison of volume-control and pressure-control ventilation during one-lung ventilation
Authors
염종훈신우종김유정심재항전우재조상윤김경헌
Issue Date
May-2009
Publisher
대한마취통증의학회
Keywords
One-lung ventilation; Peak inspiratory airway pressure; Pressure control ventilation; Volume control ventilation; One-lung ventilation; Peak inspiratory airway pressure; Pressure control ventilation; Volume control ventilation
Citation
Korean Journal of Anesthesiology, v.56, no.5, pp.492 - 496
Indexed
KCI
Journal Title
Korean Journal of Anesthesiology
Volume
56
Number
5
Start Page
492
End Page
496
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176760
ISSN
2005-6419
Abstract
Background: We hypothesized that pressure control ventilation allows a more even distribution in the lung and better maintenance of the mean airway pressure than is achieved with volume control ventilation. We try to compare the effect of pressure control ventilation (PC) with that of volume control ventilation without an end-inspiratory pause (VC) during one-lung ventilation (OLV) in an anesthetized, paralyzed patient for performing thoracopic bullectomy of the lung. Methods: We ventilated 20 patients with VC and PC after the insertion of a thoracoscope in continual order for, at least for 15 minutes, for each, VC and PC procedure. At the end of VC and PC, the respiratory mechanics, gasometrics, and hemodynamic parameters were measured and collected. Results: We found no significant differences between VC and PC except for the peak inspiratory airway pressure (PIP), the mean airway pressure and the arterial oxygen partial pressure (PaO2). The PIP was significantly decreased from 27.0 ± 6.0 cmH2O (VC) to 21.8 ± 5.4 cmH2O (PC). The mean airway pressure was significantly increased from 8.6 ± 1.6 ㎝H2O (VC) to 9.4 ± 2.0 cmH2O (PC), and the PaO2 was significantly increased from 252.9 ± 97.3 mmHg (VC) to 285.2 ± 103.8 mmHg (PC). Conclusions: If PC allows mechanical ventilation with the same tidal volume and respiratory rate as VC during OLV, then PC significantly increases the PaO2 but this is not clinically significant, and the PC significantly decreases the PIP, which induces barotrauma or volutrauma when the PIP is excessively high.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Woo Jae photo

Jeon, Woo Jae
COLLEGE OF MEDICINE (DEPARTMENT OF ANESTHESIA AND MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE