Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

저나트륨혈증 환자의 진단과 치료에서 연속적인 생리식염수 및 수분 부하검사와 Barsoum-Levine 공식의 유용성The Effectiveness of Sequential Intravenous Saline and Oral Water Loading Tests and Barsoum-Levine Formula for Managing Hyponatremic Patients: 2 Case Reports

Other Titles
The Effectiveness of Sequential Intravenous Saline and Oral Water Loading Tests and Barsoum-Levine Formula for Managing Hyponatremic Patients: 2 Case Reports
Authors
이주학김원준노유석김연재고영선한상웅김호중
Issue Date
Nov-2008
Publisher
대한신장학회
Keywords
Hyponatremia; Formula; Inappropriate ADH syndrome
Citation
Kidney Research and Clinical Practice, v.27, no.6, pp.726 - 732
Indexed
KCI
Journal Title
Kidney Research and Clinical Practice
Volume
27
Number
6
Start Page
726
End Page
732
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/177653
ISSN
2211-9132
Abstract
In hyponatremic patients, the assessment of extracellular fluid volume plays an essential step in diagnosing the etiology of hyponatremia and deciding how to manage it. Although various laboratory tests and diagnostic procedures have been developed for differential diagnosis of hyponatremia, there still are limits to the evaluation of the status of extracellular fluid volume due to the data that overlaps each other, leading to the difficulty in diagnosing between euvolemia and hypovolemia. Also, there is no consensus about how to guide the type and amount of fluid therapy despite many formulas including Adrogue-Madias and Barsoum-Levine formulas have been suggested. Hereby, we are reporting two hyponatremic patients (102 and 105 mEq/L) admitted simultaneously with indistinct volume status on initial clinical and laboratory examinations, but were clarified as euvolemic hyponatremia (syndrome of inappropriate antidiuretic hormone secretion) in one and hypovolemic hyponatremia in the other case after sequential intravenous saline (2 L over 24 hrs) and oral water (20 mL/kg) loading tests. When serum sodium values calculated by the above-mentioned two formulas were compared with actually measured ones during saline loading test in these cases, the Barsoum-Levine formula revealed almost no discrepancy between both the values while the Adrogue-Madias formula underestimated the measured value.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang-Woong photo

Han, Sang-Woong
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE