Proton-Induced Gamma-ray Emission System with a Compton Suppression Detector and Pulsed Beam
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Gi Dong | - |
| dc.contributor.author | Choi, Han Woo | - |
| dc.contributor.author | Woo, Hyung-Joo | - |
| dc.contributor.author | Kim, Yong Kyun | - |
| dc.date.accessioned | 2022-12-21T01:07:25Z | - |
| dc.date.available | 2022-12-21T01:07:25Z | - |
| dc.date.issued | 2008-10 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/177839 | - |
| dc.description.abstract | The prompt gamma-rays, which are emitted from a sample under the proton-induced gamma-ray emission (PIGE) reaction, are always interfered with by the signals corresponding to natural environmental radiation and beam-associated backgrounds. These interferences can be decreased by selecting those events that correspond to the moment of arrival of the ion burst at the target by using a pulsed beam and by using a Compton suppression detector to remove the Compton background under a photopeak. The characteristics of a PIGE system with these features were investigated by quantitatively analyzing the composition of a geological standard sample of SCo-1. Especially, a quantitative analysis of Na based on Si was shown to have an improvement of 58 %. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Proton-Induced Gamma-ray Emission System with a Compton Suppression Detector and Pulsed Beam | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.53.1859 | - |
| dc.identifier.scopusid | 2-s2.0-55949084567 | - |
| dc.identifier.wosid | 000260100400016 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.53, no.4, pp 1859 - 1865 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 53 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 1859 | - |
| dc.citation.endPage | 1865 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001471260 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordPlus | PIGE | - |
| dc.subject.keywordAuthor | PIGE | - |
| dc.subject.keywordAuthor | SCo-1 | - |
| dc.subject.keywordAuthor | Compton suppression detector | - |
| dc.subject.keywordAuthor | Pulsed beam | - |
| dc.subject.keywordAuthor | (p,p 'gamma) reaction | - |
| dc.identifier.url | https://www.jkps.or.kr/journal/view.html?volume=53&number=4&spage=1859&year=2008 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.