Cited 0 time in
Development of a High Pressure Xe Ionization Chamber for Environmental Radiation Spectroscopy
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Han Soo | - |
| dc.contributor.author | Kim, Yong Kyun | - |
| dc.contributor.author | Park, Se Hwan | - |
| dc.contributor.author | Ha, Jang Ho | - |
| dc.contributor.author | Kim, Jong Kyung | - |
| dc.contributor.author | Kang, Sang Mook | - |
| dc.contributor.author | Cho, Seung Yeon | - |
| dc.contributor.author | Kim, Do Hyun | - |
| dc.contributor.author | Chung, Eui Kwon | - |
| dc.date.accessioned | 2022-12-21T02:49:52Z | - |
| dc.date.available | 2022-12-21T02:49:52Z | - |
| dc.date.issued | 2008-06 | - |
| dc.identifier.issn | 0022-3131 | - |
| dc.identifier.issn | 1881-1248 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/178549 | - |
| dc.description.abstract | A High Pressure Xenon ionization chamber is a promising radiation detector for environmental radiation measurement due to its radiation hardness, its physical rigidity, and its capability of operation at a high temperature up to about 170 degrees C. A cylindrical high pressure xenon ionization chamber, which was configured with a shielding mesh to improve its energy resolution, was designed on the basis of an electron transfer simulation code (EGSnrc) to extract an optimal density of Xe gas and a thickness of the chamber wall. An electron drift simulation code, Garfield, which was coupled with a Maxwell electric filed calculator, was also employed for the electron drift simulations due to the geometry of the shielding mesh. Shielding inefficiency was also calculated. A spherical ionization chamber was also designed and fabricated to monitor environmental radiation. A noble gas system was constructed to create a noble gas with a high purity and to inject the noble gas Lip to 60 atm. The combination of an oxygen absorbent (Oxisorb), a molecular sieve, and a high temperature getter can minimize the electro-negative impurities, such as the O-2 and N-2 gas, to below about several ppb levels. Preliminary tests such as leakage currents, saturation currents, and gas leak test were performed. The performance of the two fabricated ionization chambers at a low dose rate was tested by using a conventional shadow technique with a NIST certified 33.52 MBq Ra-226 source in the calibration room at KAERI. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Atomic Energy Society of Japan/Nihon Genshiroku Gakkai | - |
| dc.title | Development of a High Pressure Xe Ionization Chamber for Environmental Radiation Spectroscopy | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1080/00223131.2008.10875869 | - |
| dc.identifier.scopusid | 2-s2.0-84912018994 | - |
| dc.identifier.wosid | 000267196000099 | - |
| dc.identifier.bibliographicCitation | Journal of Nuclear Science and Technology, pp 383 - 386 | - |
| dc.citation.title | Journal of Nuclear Science and Technology | - |
| dc.citation.startPage | 383 | - |
| dc.citation.endPage | 386 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | XENON | - |
| dc.subject.keywordPlus | Density of gases | - |
| dc.subject.keywordPlus | Gas detectors | - |
| dc.subject.keywordPlus | Gases | - |
| dc.subject.keywordPlus | Ionization chambers | - |
| dc.subject.keywordPlus | Leakage currents | - |
| dc.subject.keywordPlus | Mesh generation | - |
| dc.subject.keywordPlus | Molecular oxygen | - |
| dc.subject.keywordPlus | Molecular sieves | - |
| dc.subject.keywordPlus | Optimal systems | - |
| dc.subject.keywordPlus | Radiation | - |
| dc.subject.keywordPlus | Radiation shielding | - |
| dc.subject.keywordAuthor | high-pressure Xe | - |
| dc.subject.keywordAuthor | ionization chamber | - |
| dc.subject.keywordAuthor | environmental radiation | - |
| dc.subject.keywordAuthor | shadow shielding technique | - |
| dc.subject.keywordAuthor | EGSnrc | - |
| dc.subject.keywordAuthor | Garfield | - |
| dc.subject.keywordAuthor | shielding mesh | - |
| dc.identifier.url | https://www.tandfonline.com/doi/abs/10.1080/00223131.2008.10875869 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
