Cited 0 time in
Fabrication of CZT Planar-Type Detectors and Comparison of their Performance
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Se-Hwan | - |
| dc.contributor.author | Ha, Jang-Ho | - |
| dc.contributor.author | Lee, Jae-Hyung | - |
| dc.contributor.author | Cho, Yoon-Ho | - |
| dc.contributor.author | Kim, Han-Soo | - |
| dc.contributor.author | Kang, Sang-Mook | - |
| dc.contributor.author | Kim, Yong-Kyun | - |
| dc.date.accessioned | 2022-12-21T02:50:17Z | - |
| dc.date.available | 2022-12-21T02:50:17Z | - |
| dc.date.issued | 2008-06 | - |
| dc.identifier.issn | 0022-3131 | - |
| dc.identifier.issn | 1881-1248 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/178552 | - |
| dc.description.abstract | CZT is one of the most promising materials for X-ray and gamma-ray radiation detectors operated at room temperature. We have studied the fabrication process of the CZT planar-type detector, which includes the physical and chemical surface treatment, the fabrication of metal contact, and the surface passivation. CZT planar-type detectors with various metal-semiconductor contacts were made. The dark current and the gamma-rays from Am-241 were measured with each detector, and they were compared. From the above studies, the effective fabrication method of CZT detector could be deduced. Our work could be helpful to fabricate the high resolution CZT detector, which could be used in various application areas such as nuclear medicine, radiation safety, X-ray and gamma-ray astronomy and homeland security | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Atomic Energy Society of Japan/Nihon Genshiroku Gakkai | - |
| dc.title | Fabrication of CZT Planar-Type Detectors and Comparison of their Performance | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1080/00223131.2008.10875860 | - |
| dc.identifier.scopusid | 2-s2.0-84911999857 | - |
| dc.identifier.wosid | 000267196000090 | - |
| dc.identifier.bibliographicCitation | Journal of Nuclear Science and Technology, pp 348 - 351 | - |
| dc.citation.title | Journal of Nuclear Science and Technology | - |
| dc.citation.startPage | 348 | - |
| dc.citation.endPage | 351 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | PHOTOLUMINESCENCE | - |
| dc.subject.keywordPlus | CDTE | - |
| dc.subject.keywordPlus | RAY | - |
| dc.subject.keywordAuthor | CZT detector | - |
| dc.subject.keywordAuthor | Planar-type detector | - |
| dc.subject.keywordAuthor | Indium | - |
| dc.subject.keywordAuthor | Gold | - |
| dc.subject.keywordAuthor | Metal-semiconductor contact | - |
| dc.identifier.url | https://www.tandfonline.com/doi/abs/10.1080/00223131.2008.10875860 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.