Cited 0 time in
Thermal annealing of metal-semiconductor contact for CZT detectors
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Se-hwan | - |
| dc.contributor.author | Ha, Jang Ho | - |
| dc.contributor.author | Lee, Jae-hyung | - |
| dc.contributor.author | Kim, Han-soo | - |
| dc.contributor.author | Kim, Yong Kyun | - |
| dc.date.accessioned | 2022-12-21T05:44:16Z | - |
| dc.date.available | 2022-12-21T05:44:16Z | - |
| dc.date.issued | 2007-10 | - |
| dc.identifier.issn | 1095-7863 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179459 | - |
| dc.description.abstract | CZT can be used for high-resolution X-ray and γ - ray spectroscopy at room temperature. Previously thermal annealing process has been studied to decrease the leakage current of the detector and obtain the stable detector performance. Because of its low work function, indium can be used as the metal contact for CZT Schottky detector. The low temperature annealing effect on In/CZT contact was studied in our work. A CZT Schottky detector with indium/CZT/gold structure was fabricated. The leakage current and the energy resolution of each detector were measured. The detector was annealed for 10 hours in vacuum, and for 2,4, 8 hours in air. The leakage current and the energy resolution of the detector were measured after the annealing process and they were compared with the data before the annealing. It was found that the detector performance of CZT Schottky detector was enhanced with the low temperature annealing process in air. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.title | Thermal annealing of metal-semiconductor contact for CZT detectors | - |
| dc.type | Article | - |
| dc.identifier.doi | 10.1109/NSSMIC.2007.4437288 | - |
| dc.identifier.scopusid | 2-s2.0-48349137984 | - |
| dc.identifier.bibliographicCitation | IEEE Nuclear Science Symposium Conference Record, v.2, pp 1521 - 1524 | - |
| dc.citation.title | IEEE Nuclear Science Symposium Conference Record | - |
| dc.citation.volume | 2 | - |
| dc.citation.startPage | 1521 | - |
| dc.citation.endPage | 1524 | - |
| dc.type.docType | Conference Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordPlus | Annealing | - |
| dc.subject.keywordPlus | Medical imaging | - |
| dc.subject.keywordPlus | Metal analysis | - |
| dc.subject.keywordPlus | Semiconductor detectors | - |
| dc.subject.keywordPlus | Z transforms | - |
| dc.subject.keywordPlus | Annealing effects | - |
| dc.subject.keywordPlus | Annealing processes | - |
| dc.subject.keywordPlus | CZT detectors | - |
| dc.subject.keywordPlus | Detector performances | - |
| dc.subject.keywordPlus | Energy resolutions | - |
| dc.subject.keywordPlus | High resolutions | - |
| dc.subject.keywordPlus | In vacuums | - |
| dc.subject.keywordPlus | Low temperatures | - |
| dc.subject.keywordPlus | Metal contacts | - |
| dc.subject.keywordPlus | Room temperatures | - |
| dc.subject.keywordPlus | Schottky detectors | - |
| dc.subject.keywordPlus | Semiconductor contacts | - |
| dc.subject.keywordPlus | Thermal annealing | - |
| dc.subject.keywordPlus | Detectors | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/4437288 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
