Retrofit of artificially perforated shear wall in existing dominant wall structure
- Authors
- Choi, Chang Sik; Choi, Y.C.; Choi, H.K.; Lee, M.S.
- Issue Date
- Sep-2007
- Publisher
- Trans Tech Publications Ltd
- Keywords
- Carbon fiber sheet; Opening; Remodeling; Shear wall; Steel plate
- Citation
- Key Engineering Materials, v.348-349, pp.917 - 920
- Indexed
- SCOPUS
- Journal Title
- Key Engineering Materials
- Volume
- 348-349
- Start Page
- 917
- End Page
- 920
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179612
- DOI
- 10.4028/0-87849-448-0.917
- ISSN
- 1013-9826
- Abstract
- A series of three shear wall specimens were tested under constant axial stress and reversed cyclical lateral loading in order to evaluate the seismic retrofit that had been proposed for the shear wall with the opening induced by remodeling. One of these specimens was tested in the as-built condition and the other two were retrofitted prior to testing. The retrofit involved the use of carbon fiber sheets and steel plates (a thickness of 3mm) over the entire face of the wall. The test results showed that the failed specimens had shear fractures and that two different types of retrofitting strategies had different effects on the strengths of each specimen.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > 서울 건축공학부 > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179612)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.