Interface shear strength of Carbon Fiber Mesh (CFM) attached to RC surface for external reinforcing

Authors
Seo, Soo-YeonYun, Hyun-DoChoi, Chang SikChoi, Ki-Bong
Issue Date
Nov-2006
Publisher
Trans Tech Publications Ltd.
Keywords
Anchorage capacity; Carbon Fiber Mesh (CFM); Clips; Interface shear strength; Retrofit; Two dimensional grid
Citation
Key Engineering Materials, v.324-325 II, pp 799 - 802
Pages
4
Indexed
SCOPUS
Journal Title
Key Engineering Materials
Volume
324-325 II
Start Page
799
End Page
802
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180748
DOI
10.4028/www.scientific.net/KEM.324-325.799
ISSN
1013-9826
1662-9795
Abstract
The strengthening of concrete structures in situ with externally bonded carbon fiber is increasingly being used for repair and rehabilitation of existing structures since carbon fiber has good mechanical properties such as high tensile strength, good resistances to corrosion, and low self-weight, which are attractive for retrofitting of RC member. In using Carbon Fiber Mesh (CFM) as a retrofit material for RC member, most important structural property that should be developed is the bond strength between RC member and CFM. The additional strength increment by CFM can be developed if the bond strength is sufficient. If it is not, the strengthening effect can not be expected due to the bond failure between concrete and CFM. A direct tensile test was performed in order to find the variation of bond strength and load-displacement response of CFM attached to the concrete and the result is presented in this paper. The key parameters of the test are the location of clip for the installation of CFM, number of clips and thickness of cover mortar. Test results indicate that the bond strength is dependent on the number of clips and maximized at clip numbers of three per each rod. In specimens without clips, the highest strength was found in the specimen with cove mortar of 30mm and lowest one in specimen with largest mortar thickness. This means that in too much thick of cover mortar, it seems that the amount of drying shrinkage is increased and this reduces rather than improves the bond strength.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Chang Sik photo

Choi, Chang Sik
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE