Fabrication of a GEM-based gas detector for thermal neutron measurement
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Se-Hwan | - |
dc.contributor.author | Kim, Han-Soo | - |
dc.contributor.author | Ha, Jang-Ho | - |
dc.contributor.author | Kim, Yong-Kyun | - |
dc.contributor.author | Kim, Jong Kyung | - |
dc.date.accessioned | 2022-12-21T09:55:32Z | - |
dc.date.available | 2022-12-21T09:55:32Z | - |
dc.date.created | 2022-09-16 | - |
dc.date.issued | 2006-11 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180780 | - |
dc.description.abstract | GEM (gas electron multiplier) has been studied in many application areas. One of the interesting application areas is the measurement of thermal neutrons. A thin-film neutron converter, B-10, which is widely used as a neutron converter, was installed in the GEM-based gas chamber, and the charged ions that were generated from the neutron interactions with the converter could be measured. The optimum thickness of B-10 film to measure thermal neutrons was obtained with a Monte-Carlo calculation. However, when pure B-10 is coated as a thin film, it peels off very easily. We employed a new method to make a stable B-10 film. The B-10 was evaporated to make a film with a structure of segmented rectangles, which reduced the tension on the film. Neutrons could be measured successfully with the GEM-based gas detector equipped with the B-10 film. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.title | Fabrication of a GEM-based gas detector for thermal neutron measurement | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Yong-Kyun | - |
dc.identifier.scopusid | 2-s2.0-33845571000 | - |
dc.identifier.wosid | 000242057300009 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.49, no.5, pp.1939 - 1943 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 49 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 1939 | - |
dc.citation.endPage | 1943 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001199808 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.subject.keywordPlus | NEXT-GENERATION | - |
dc.subject.keywordAuthor | CEM | - |
dc.subject.keywordAuthor | thermal neutron | - |
dc.subject.keywordAuthor | Monte-Carlo calculation | - |
dc.subject.keywordAuthor | evaporation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.