Cited 0 time in
Dry etching of TaN/HfO2 gate-stack structure in BCl3/Ar/O-2 inductively coupled plasmas
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Shin, Myung Hun | - |
| dc.contributor.author | Park, Myoung-Sung | - |
| dc.contributor.author | Lee, Nae-Eung | - |
| dc.contributor.author | Kim, Jiyoung | - |
| dc.contributor.author | Kim, Chung Ywong | - |
| dc.contributor.author | Ahn, Jinho | - |
| dc.date.accessioned | 2022-12-21T10:54:46Z | - |
| dc.date.available | 2022-12-21T10:54:46Z | - |
| dc.date.issued | 2006-07 | - |
| dc.identifier.issn | 0734-2101 | - |
| dc.identifier.issn | 1520-8559 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/181229 | - |
| dc.description.abstract | In this work, etching characteristics of TaN(200 nm)/HfO2(80 nm) gate-stack structures on Si substrate were investigated by varying the process parameters such as BCl3/(BCl3+Ar+O-2) gas mixing ratio (Q), top-electrode power, dc self-bias voltage (V-dc), and overetch time in an inductively coupled plasma etcher. To understand the role of the etch gas chemistry, we measure the relative changes in the optical emission intensity of ions and radicals in the plasma as well as in the chemical binding states of the etched TaN surfaces. We used optical emission spectroscopy and x-ray photoelectron spectroscopy respectively. The results showed that BCl3/Ar/O-2 plasma is more effective in etching the oxidized TAN than Cl-2/Ar/O-2 or HBr/Ar/O-2 plasma. It is believed that the B radical species removes the oxygen atoms on the oxidized TaN surface more effectively by forming volatile boron-oxygen-chlorine compounds, such as trichloroboroxin (BOCl)(3)), boron oxychloride (BOCl), and boron dioxide. The measurement data also indicated that high etch selectivities of the TaN to the HfO2 layer could be obtained at the low V-dc, high top-electrode power, and shorter overetch time. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Institute of Physics | - |
| dc.title | Dry etching of TaN/HfO2 gate-stack structure in BCl3/Ar/O-2 inductively coupled plasmas | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1116/1.2210944 | - |
| dc.identifier.scopusid | 2-s2.0-33745513672 | - |
| dc.identifier.wosid | 000239048100086 | - |
| dc.identifier.bibliographicCitation | Journal of Vacuum Science and Technology A, v.24, no.4, pp 1373 - 1379 | - |
| dc.citation.title | Journal of Vacuum Science and Technology A | - |
| dc.citation.volume | 24 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 1373 | - |
| dc.citation.endPage | 1379 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Coatings & Films | - |
| dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
| dc.subject.keywordPlus | RAY MASK ABSORBER | - |
| dc.subject.keywordPlus | HFO2 GATE | - |
| dc.subject.keywordPlus | THIN-FILMS | - |
| dc.subject.keywordPlus | METAL GATE | - |
| dc.subject.keywordPlus | ELECTRICAL-PROPERTIES | - |
| dc.subject.keywordPlus | THERMAL-STABILITY | - |
| dc.subject.keywordPlus | SI | - |
| dc.subject.keywordPlus | ELECTRODE | - |
| dc.subject.keywordPlus | CHLORINE | - |
| dc.subject.keywordPlus | GAS | - |
| dc.identifier.url | https://avs.scitation.org/doi/10.1116/1.2210944 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.