Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

수직진동 사용성을 고려한 플랫 플레이트 슬래브의 최소두께 제안Minimum Thickness of Flat Plate Slab Satisfying Floor Vibration Criteria

Other Titles
Minimum Thickness of Flat Plate Slab Satisfying Floor Vibration Criteria
Authors
한상환김동현이민정
Issue Date
May-2006
Publisher
한국소음진동공학회
Keywords
Flat Plate; 플랫 플레이트; Slab Thickness; 바닥 두께; Floor Vibration; 바닥 진동; Random Variable; 불확실 변수; Reliability Analysis; 신뢰성 분석
Citation
한국소음진동공학회논문집, v.16, no.6, pp.574 - 581
Indexed
KCI
Journal Title
한국소음진동공학회논문집
Volume
16
Number
6
Start Page
574
End Page
581
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/181438
ISSN
1598-2785
Abstract
Flat plate slab systems are more economical rather than reinforced concrete frame systems because flat plate slab system reduces story height. Furthermore flat plate systems are more popularly needed in construction practice due to flexibility of plan. Korean Concrete Provisions 2003 provide the minimum thickness of the slab that satisfies serviceability requirement to the static displacement. However, floor thickness in residence buildings may not satisfy the floor vibration criteria although the thickness satisfies the serviceability requirements in current design provisions. This study estimates the dynamic properties of floor vibration for existing flat plate slabs, and proposes the slab thickness satisfying the floor vibration criteria. The dynamic response analysis using finite element method and reliability analysis are carried out for this purpose.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Whan photo

Han, Sang Whan
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE