Cooling Performance Prediction for Hydraulic Thermoelectric Radiant Cooling Panels with Experimental Validationopen access

Authors
Kim, MinseongKang, Yong-KwonJoung, JaewonJeong, Jae-Weon
Issue Date
Dec-2022
Publisher
MDPI
Keywords
thermoelectric module; radiant cooling panel; cooling performance prediction model; design factor; parametric analysis; impact analysis
Citation
SUSTAINABILITY, v.14, no.23, pp.1 - 17
Indexed
SCIE
SSCI
SCOPUS
Journal Title
SUSTAINABILITY
Volume
14
Number
23
Start Page
1
End Page
17
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/182119
DOI
10.3390/su142316214
ISSN
2071-1050
Abstract
Thermoelectric technology has been developed as a substitute for existing refrigerants in heating, ventilation, and air-conditioning system applications for building decarbonization. A hydraulic thermoelectric radiant cooling panel (hTERCP) operated based on the Peltier effect can alternate a conventional cooling system using a chiller with refrigerators. This study aimed to develop a cooling performance prediction model for a hTERCP-integrated free cooling system according to the desirable range of five design factors. A mockup model of the hTERCP was constructed and tested in an environmental chamber to verify the proposed simulation model. The simulation and the experimental analysis confirmed that the heat rejection performance of the thermoelectric module (TEM) significantly affects the cooling performance of the hTERCP. The cooling water temperature was the primary design factor for releasing heat from the hot side of the TEM and significantly influenced the cooling performance of the hTERCP. A parametric analysis of the five design factors was conducted to investigate a method for improving the coefficient of performance (COP) of the hTERCP. The cooling water temperature affected the COP by 38.6-45.7%, and the heat exchange area of the cooling surface greatly influenced the cooling performance by 41.4%. The cooling water flow rate, heat exchange effectiveness of the water block, and heat resistance of the hot side were confirmed to have relatively little influence as 9.7-10.2%, 11.9-24.8%, and 0.7-11.1%, respectively.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE