| dc.description.abstract | The design process for optimizing a real-time 16N beta monitoring system inside a containment building was developed in this study. The purpose of the system is to detect the unidentified small leaks (less than 0.5 gpm/h) of the primary and secondary coolant system of a pressurized water reactor, based on radiation measurements. The system is located at the annulus zone of the reactor containment building, away from the high radiation background, and detects the 16N beta particles that are transported to the system after collection at the leakage points of the reactor coolant system. The specifications of the overall system were determined using Monte Carlo and computational fluid dynamics simulations. In particular, the optimization process for the shielding and collection cavity geometry has been described. A 5 cm lead shielding was determined considering the efficient weight reduction of the system and the radiation tolerance of the detector system over the reactor life. Assuming a 16N concentration of 1000 Bq/cc in the designed air collection cavity (2000 cc volume), the signal-to-noise ratio was evaluated to be approximately 2.2, and the leakage could be confirmed in the background radiation environment in the annulus zone. Based on the derived specifications, a system prototype was manufactured considering structural safety. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Design optimization of real-time in-containment 16N beta detection system | - |
| dc.title.alternative | Design optimization of real-time in-containment 16N beta detection system | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1007/s40042-023-00728-7 | - |
| dc.identifier.scopusid | 2-s2.0-85146764113 | - |
| dc.identifier.wosid | 000915827000002 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.82, no.3, pp 251 - 256 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 82 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 251 | - |
| dc.citation.endPage | 256 | - |
| dc.type.docType | Article in Press | - |
| dc.identifier.kciid | ART002930178 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordAuthor | Beta detector | - |
| dc.subject.keywordAuthor | Leakage monitoring system | - |
| dc.subject.keywordAuthor | N-16 detector | - |
| dc.subject.keywordAuthor | Reactor coolant system | - |
| dc.identifier.url | https://link.springer.com/article/10.1007/s40042-023-00728-7 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.