A Study on Harmonic Reduction According to the Combination of the Number of Pole/slots of an External Synchronous Generator for Drones
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jungwon | - |
dc.contributor.author | Kang, Junho | - |
dc.contributor.author | Jung, Dong-Hoon | - |
dc.contributor.author | Jin, Chang-Sung | - |
dc.contributor.author | Won, Sung-Hon | - |
dc.contributor.author | Lee, Ju | - |
dc.date.accessioned | 2023-02-21T06:04:21Z | - |
dc.date.available | 2023-02-21T06:04:21Z | - |
dc.date.created | 2023-02-08 | - |
dc.date.issued | 2022-11 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/182402 | - |
dc.description.abstract | In this paper, the harmonic characteristics according to the pole/slots combination of an external type synchronous generator for drones were compared. Four models of permanent magnet synchronous generators with fractional slots were selected to analyze and deal with the harmonic content of the no-load back EMF. Through comparison using FEM, one pole number slot combination with the best THD characteristics was selected among the four models, and the response surface method was applied to the selected model to design an optimal design for further harmonic reduction. The reliability of the optimal design result was verified by comparing the optimal design result with the FEM result of the basic model. The performance of the selected model was verified through actual manufacturing and testing, and the reliability of the FEM analysis model was confirmed. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
dc.title | A Study on Harmonic Reduction According to the Combination of the Number of Pole/slots of an External Synchronous Generator for Drones | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Ju | - |
dc.identifier.doi | 10.1109/ICEMS56177.2022.9983233 | - |
dc.identifier.scopusid | 2-s2.0-85146361244 | - |
dc.identifier.wosid | 000932099800319 | - |
dc.identifier.bibliographicCitation | 2022 International Conference on Electrical Machines and Systems, ICEMS 2022, pp.1 - 5 | - |
dc.relation.isPartOf | 2022 International Conference on Electrical Machines and Systems, ICEMS 2022 | - |
dc.citation.title | 2022 International Conference on Electrical Machines and Systems, ICEMS 2022 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 5 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.subject.keywordPlus | Drones | - |
dc.subject.keywordPlus | Harmonic analysis | - |
dc.subject.keywordPlus | Optimal systems | - |
dc.subject.keywordPlus | Permanent magnets | - |
dc.subject.keywordPlus | Reliability analysis | - |
dc.subject.keywordPlus | Synchronous generators | - |
dc.subject.keywordPlus | Fractional slot | - |
dc.subject.keywordPlus | Harmonic characteristics | - |
dc.subject.keywordPlus | Harmonic reduction | - |
dc.subject.keywordPlus | Harmonics content | - |
dc.subject.keywordPlus | No load | - |
dc.subject.keywordPlus | Number of poles | - |
dc.subject.keywordPlus | Optimal design | - |
dc.subject.keywordPlus | Permanent magnet synchronoi generator for drone application | - |
dc.subject.keywordPlus | Permanent magnet synchronous generator | - |
dc.subject.keywordPlus | Pole/slot combinations | - |
dc.subject.keywordAuthor | Optimal design | - |
dc.subject.keywordAuthor | Permanent Magnet Synchronous Generator for Drone application | - |
dc.subject.keywordAuthor | Pole/Slots Combination | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/9983233 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.