Comparative analysis of sizing procedure for cooling and water heating cascade heat pump applied to a residential buildingopen access

Authors
Kim, Beom-JunJo, Su-YoungJeong, Jae-Weon
Issue Date
Mar-2023
Publisher
ELSEVIER
Keywords
Cascade heat pump; Multi-functional system; Sizing procedure; Residential building; Intermediate heat exchanger; Comparative analysi
Citation
CASE STUDIES IN THERMAL ENGINEERING, v.43, pp.1 - 17
Indexed
SCIE
SCOPUS
Journal Title
CASE STUDIES IN THERMAL ENGINEERING
Volume
43
Start Page
1
End Page
17
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/182431
DOI
10.1016/j.csite.2023.102775
ISSN
2214-157X
Abstract
An appropriate design strategy suitable for the purpose of a building should be considered to apply a cascade heat pump system for multiple functions to buildings. The purpose of this study is to propose a sizing process and evaluate a capacity calculation simulation of air-to-air/water cascade heat pump systems applied in residential buildings that supply indoor cooling and hot water. A simulation study was performed by dividing the capacity calculation method suitable for the building conditions into two cases when this multi-functional cascade heat pump system was applied to a residential building. Case 1 was a sizing method that considered a low-cycle heat pump for indoor cooling. The existing heat pump sizing method for the hot-water supply used in the previous study was set to Case 2. The heat pump simulation and heat calculations were conducted based on thermodynamic theoretical equations. A simulation tool capable of dynamic thermal load analysis was used for model building. Detailed building information was entered in accordance with design standards. The results showed that Case 1 completely satisfies both the cooling and hot-water supply performance of the heat pump compared to Case 2. Based on Case 1, when the temperature of the intermediate heat exchanger was 10 degrees C higher than the outdoor temperature, the air volume of the indoor unit and the outdoor unit was found to be 941 m3/h at an appropriate air volume rate. In addition, the energy consumption was also the lowest at 2.29 kW h, and the maximum system COP of 6.0 was achieved.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE