Geant4 electromagnetic physics model assessment for RBE-weighted dose calculation of carbon-ion radiotherapy

Authors
Kang, Hyo KyeongHan, Min CheolYun, YongdoLee, Se HyungKim, Chan HyeongKim, Jin Sung
Issue Date
Dec-2022
Publisher
KOREAN PHYSICAL SOC
Keywords
Carbon-ion radiotherapy; Relative biological effectiveness; Electromagnetic physics model; Geant4; Microdosimetry kinetic model
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.81, no.11, pp.1059 - 1063
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
81
Number
11
Start Page
1059
End Page
1063
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185397
DOI
10.1007/s40042-022-00568-x
ISSN
0374-4884
Abstract
Carbon-ion radiotherapy (CIRT) is being increasingly practiced owing to its advantages over conventional photon-based radiotherapy. Several CIRT-related dose calculation studies considering the biological effects of carbon ions were performed using the Geant4 Monte Carlo toolkit. For accurate RBE-weighted dose calculation in CIRT, the Geant4 physics models used in a simulation code need to be validated. Previous studies have validated the hadronic physics model of Geant4, but a validation study for electromagnetic (EM) physics models is missing. Therefore, we validated the Geant4 EM physics models for carbon RBE-weighted dose calculation. For the validation process in Geant4, the geometry used in the Microdosimetric kinetic model was irradiated by mono-energy beams between 0.1 and 1000 MeV/u of six elements (H, He, Li, Be, B, and C). The imparted dose calculated using various EM physics models is compared with the theoretical value. A G4EMStandardPhysics-based model is confirmed to result in breaking points for RBE-weighted dose calculations, whereas no such breaking points are observed when using our physics model and Geant4-DNA physics model. Because the breaking points observed in the results may induce uncorrected dose calculations, validating the EM physics models is recommended when performing carbon RBE-weighted dose calculation using Geant4.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE